hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
PIV Visualisation Study in a Two-Dimensional Room Model with Rapid Time Varying Ventilation Flow Rates
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering, Building science - installation technology. (Inomhusmiljö)
KTH.
KTH.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering, Building science - installation technology. (Inomhusmiljö)ORCID iD: 0000-0003-1121-2394
2011 (English)In:  , tapir academic press , 2011Conference paper, Published paper (Refereed)
Abstract [en]

Optimal control of inlet jet flows is of wide applicative interest in order to enhance mixing and reduce stagnation in a ventilated room. The general approach in mechanical ventilation is to use a constant flow rate forced convection system providing the ventilation air. This type of ventilation may cause several problems such as draught, stagnation at certain occupied locations, and subsequently low ventilation efficiencies. An alternative to increase the ventilation quality that has been of interest in this study is to introduce flow variations, which is considered as a potential to reduce stagnation and increase efficiency of the ventilation. The study was conducted as a model experiment in a small-scale, two-dimensional (2-D) room model with dimensions 30´20´0.9 cm3 with water as operating fluid. The size of the model made it possible to investigate the 2-D velocity vector field within the entire room using Particle Image Velocimetry (PIV) method and further consequent dynamical and statistical analyses have been done from the resulted PIV vector fields. The comparison between cases of constant flow rate and flow variations have been conducted for the cases of two set of base flow rates and for each one, the cases of constant flow rate and flow variations with frequencies of 0.3, 0.4 and 0.5 Hz, is considered. In this investigation we show that the calm region, with a large stagnation zone, without pulsating inflow condition becomes more active in the sense that the stagnation points are moved and that the small-scale structures are grown for increasing pulsation frequency.

Place, publisher, year, edition, pages
tapir academic press , 2011.
Keywords [en]
PIV, room model, ventilation, varying flow rate
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hig:diva-10543ISBN: 978-82-519-2812-0 (print)OAI: oai:DiVA.org:hig-10543DiVA, id: diva2:444536
Conference
ROOMVENT 2011, Trondheim, Norway, June 19-22, 2011
Available from: 2011-09-29 Created: 2011-09-29 Last updated: 2020-11-16Bibliographically approved
In thesis
1. Investigations of Flow Patterns in Ventilated Rooms Using Particle Image Velocimetry: Applications in a Scaled Room with Rapidly Varying Inflow and over a Wall-Mounted Radiator
Open this publication in new window or tab >>Investigations of Flow Patterns in Ventilated Rooms Using Particle Image Velocimetry: Applications in a Scaled Room with Rapidly Varying Inflow and over a Wall-Mounted Radiator
2015 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

This thesis introduces and describes a new experimental setup for examining the effects of pulsating inflow to a ventilated enclosure. The study aimed to test the hypothesis that a pulsating inflow has potential to improve ventilation quality by reducing the stagnation zones through enhanced mixing. The experimental setup, which was a small-scale, two-dimensional (2D), water-filled room model, was successfully designed and manufactured to be able to capture two-dimensional velocity vectors of the entire field using Particle Image Velocimetry (PIV). Using in-house software, it was possible to conclude that for an increase in pulsation frequency or alternatively in the flow rate, the stagnation zones were reduced in size, the distribution of vortices became more homogeneous over the considered domain, and the number of vortices in all scales had increased. Considering the occupied region, the stagnation zones were moved away in a favorable direction from a mixing point of view. In addition, statistical analysis unveiled that in the far-field occupied region of the room model, stronger eddies were developed that we could expect to give rise to improved mixing. As a fundamental experimental study performed in a 2D, small-scale room model with water as operating fluid, we can logically conclude that the positive effect of enhanced mixing through increasing the flow rate could equally be accomplished through applying a pulsating inflow.

In addition, this thesis introduces and describes an experimental setup for study of air flow over a wall-mounted radiator in a mockup of a real room, which has been successfully designed and manufactured. In this experimental study, the airflow over an electric radiator without forced convection, a common room-heating technique, was measured and visualized using the 2D PIV technique. Surface blackening due to particle deposition calls for monitoring in detail the local climate over a heating radiator. One mechanism causing particle deposition is turbophoresis, which occurs when the flow is turbulent. Because turbulence plays a role in particle deposition, it is important to identify where the laminar flow over radiator becomes turbulent. The results from several visualization techniques and PIV measurements indicated that for a room with typical radiator heating, the flow over the radiator became agitated after a dimensionless length, 5.0–6.25, based on the radiator thickness.

Surface properties are among the influencing factors in particle deposition; therefore, the geometrical properties of different finishing techniques were investigated experimentally using a structured light 3D scanner that revealed differences in roughness among different surface finishing techniques. To investigate the resistance to airflow along the surface and the turbulence generated by the surfaces, we recorded the boundary layer flow over the surfaces in a special flow rig, which revealed that the types of surface finishing methods differed very little in their resistance and therefore their influence on the deposition velocity is probably small. 

Abstract [sv]

Det övergripande syftet med den första studien i avhandlingen var att undersöka hypotesen att ett pulserande inflöde till ett ventilerade utrymme har en potential till att förbättra ventilationens kvalitet genom att minska stagnationszoner och därigenom öka omblandningen. För genomförande av studien byggdes en experimentuppställning i form av en tvådimensionell (2D) småskalig modell av ett ventilerat rum. Strömningsmediet i modellen var vatten. Det tvådimensionella hastighetsfältet registrerades över hela modellen med hjälp av Particle Image Velocimetry (PIV). Vid ett stationärt tillflöde bildas ett stagnationsområde i centrum av rumsmodellen. Vid ett pulserade inflöde genererades sekundära virvlar. Med en egen utvecklad programvara var det möjligt att kvantifiera statistiken hos virvlarna. Det pulserade inflödet gjorde att inom området där det vid stationärt tillflöde fanns en stagnationszon ökade antalet virvlar i alla storlekar och fördelningen av virvlar blev mera homogen än tidigare. Detta kan förväntas ge upphov till förbättrad omblandning. Baserat på en grundläggande experimentell studie utförd i en småskalig tvådimensionell rumsmodell med vatten som strömningsmedium kan vi logiskt dra slutsatsen att ett pulserande tilluftsflöde har en potential att förbättra omblandningen. 

I en fortsatt studie i avhandlingen visuliserades och mättes hastighetsfältet och därefter beräknades statistiska värden av exempelvis medelhastighet, standardavvikelse och skjuvspänning hos hastighetsfluktuationerna i luftströmmen över en väggmonterad radiator med 2D-PIV-teknik.  Bakgrunden till studien är att en bidragande orsak till partikelavsättning på väggytor är turbofores som uppträder vid en turbulent luftström. Studien genomfördes genom uppbyggnad av en fullskalig rumsmodell. Eftersom turbulens spelar en roll vid partikelavsättning genom turbofores är det viktigt att identifiera var det laminära flödet över radiatorn blir turbulent. Resultaten baserat på visualisering och PIV-mätningar indikerade att, för ett rum med denna typ av radiatoruppvärmning, blev flödet över radiatorn turbulent efter en dimensionslös längd lika med 5,0‒6,25 gånger radiatorns tjocklek.

Ytors egenskaper är viktiga vid partikelavsättning. Därför har de geometriska egenskaperna hos några olika metoder för ytbehandling undersökts experimentellt med hjälp av en scanner för strukturerat 3D-ljus. Resultaten visar på skillnader i ytråhet hos de olika ytbehandlingsmetoderna. För att undersöka motståndet mot luftströmning längs ytan och den turbulens som genereras av ytorna registrerade vi gränsskiktsflödet över ytorna i en speciell luftströmningsrigg. Detta påvisade att motståndet hos de olika typerna av ytbehandlingsmetoder skilde sig mycket litet åt och därför är troligt vid deras påverkan på depositionshastigheten mycket liten. 

Place, publisher, year, edition, pages
Stockholm: KTH Royal Institute of Technology, 2015. p. vi, 38
Series
TRITA-IES ; 2015:02
Keywords
Particle Image Velocimetry (PIV), experimental study, structured light 3D scanning system, ventilation, varying flow rate, room model, wall-mounted radiator, air, water, flow, Particle Image Velocimetry (PIV), experimentell studie, scanningsystem för strukturerat 3D-ljus, ventilation, varierande tilluftsflöde, rumsmodell, väggmonterad radiator
National Category
Other Engineering and Technologies not elsewhere specified Civil Engineering Mechanical Engineering
Research subject
Engineering Mechanics; Civil and Architectural Engineering; Energy Technology
Identifiers
urn:nbn:se:hig:diva-19390 (URN)978-91-7595-600-8 (ISBN)
Public defence
2015-06-10, Hall F3, Lindstedtsvägen 26, Stockholm, 15:40 (English)
Opponent
Supervisors
Available from: 2015-05-27 Created: 2015-05-27 Last updated: 2020-11-16Bibliographically approved

Open Access in DiVA

No full text in DiVA

Authority records

Sattari, AmirSandberg, Mats

Search in DiVA

By author/editor
Sattari, AmirSandberg, Mats
By organisation
Building science - installation technology
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 1049 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf