hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Energibalansberäkning för flerbostadshus: projekterad energianvändning jämfört med beräknad energianvändning med uppmätta värden för Gävle Strand Etapp 1
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering.
2011 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Den beräknad mängd energi en byggnad gör av med på ett år visar huruvida den bidrar till ett hållbart samhälle eller inte. AB Gavlegårdarna arbetar inte enbart med att projektera fram förslag till lösningar för framtidens bostäder utan riktar även in sig på sitt nuvarande bestånd när det kommer till energianvändning i flerbostadshus. Gävle Strand Etapp 1 stod klart 2008 med ett bestånd av tolv byggnader som är gestaltade på fyra olika sätt. Alla med olika förutsättningar där främst brukarnas beteende såsom förbrukad mängd tappvarmvatten och hushållsel varierar kraftigt.

Under projekteringsfasen anlitades en konsult för att beräkna den köpta energin som dessa bostäder skulle använda och kom fram till en energianvändning på 92 kWh/m2,år. Gavlegårdarnas egna beräkningar som utgick ifrån de verkliga värden som uppmättes för varje lägenhet visade i september 2009 ett medelvärde för hela beståndet som låg på 114 kWh/m2,år.

AB Gavlegårdarna vill gå till botten med de problem och den extra kostnad som Gävle Strand Etapp 1 har gett upphov till genom ökad energianvändning, vilket medför att de vill utföra exakta beräkningar på varje byggnads energianvändning. Problemställningen blev därför följande:

Hur mycket påverkar FTX-systemets verkningsgrad den totala energiförbrukningen i ett flerbostadshus om systemet inte fungerar som det är tänkt? Kan ett hus bland olika geometriskt utformade hus i ett bestånd anses vara representativ för beståndet, ur energianvändningssynpunkt?

Examensarbetet går ut på att genom ett antal U-värdes– och areaberäkningar, ventilations- och luftotäthetsbedömningar, tappvarmvattenanvändning och energibrukarbeteende hos de boende, komma fram till hur mycket en utvald byggnad använder med avseende på specifik energianvändning, med enheten kWh/m2,år. Till författarens hjälp har ett energisimuleringsprogram använts som heter BV2 2010.

Resultatet visar att majoriteten av byggnaderna belägna på Gävle Strand Etapp 1 har en högre energianvändning än vad konsultens grundfall visar. Detta på grund av flera faktorer men de främsta orsakerna till den höga energianvändningen i bostäderna är den dåliga temperaturverkningsgraden i FTX-systemets värmeväxlare och brukarbeteendet med en i vissa fall relativt hög användning av tappvarmvatten.

Abstract [en]

The estimated amount of energy that a building consumes during one year indicates whether it contributes to a sustainable society or not. The communal company, AB Gavlegårdarna , that rents out apartments, works not only with designing proposals for solutions for the future housing , they also work with improving their stock when it comes to energy consumption. The multi-family buildings of Gävle Strand Phase 1 were completed in 2008 with a population of twelve buildings that are shaped in four ways.

 

During the planning phase a consultant was hired to calculate the how much energy these buildings would have to purchase and came up with an energy use of 92 kWh/m2,year. Gavlegårdarna’s own calculations are based on the actual values obtained for each apartment and in September 2009 and they showed a mean value for the whole stock, which was 114 kWh/m2,year.

 

AB Gavlegårdarna want to find a solution to the problem and reduce the extra cost that Gävle Strand Phase 1 has given rise through increased use of energy. They want to perform precise calculations on each building's energy use. The problem can be formulated as follows:

How much influence does the malfunction of a heat exchanger in a balanced ventilation system have on the total energy consumption in apartment buildings? Can a house among the various geometrically designed houses of a stock be considered to be representative when calculating the energy use of the stock as a whole?

The report deals with a number of U-value and area calculations, ventilation and air leakage assessments, domestic hot water use and energy user behavior of the residents, to work out how much a simulated building uses in terms of specific energy, with unit kWh/m2,year. An building simulation program called BV2 2010was utilized.

The results show that the majority of the buildings located in Gävle Strand Phase 1 have higher energy consumption than the consultant's basic case. This is due to several factors but the main causes of the high residential energy use is the low temperature efficiency in the FTX-system heat exchanger, the residents’ behavior and in some cases relatively high usage of hot water.

Place, publisher, year, edition, pages
2011. , p. 52
Keywords [en]
BV2, energy, air leakage, apartment buildings, kWh/m2, years, temperature efficiency, Sveby, FTX system
Keywords [sv]
BV2, energianvändning, luftläckage, flerbostadshus, kWh/m2, år, temperaturverkningsgrad, Sveby, FTX-system
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:hig:diva-11571Archive number: TEX 110720OAI: oai:DiVA.org:hig-11571DiVA, id: diva2:505974
Subject / course
Building engineering
Educational program
Högskoleingenjör
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-03-12 Created: 2012-02-27 Last updated: 2012-03-12Bibliographically approved

Open Access in DiVA

fulltext(2276 kB)1007 downloads
File information
File name FULLTEXT01.pdfFile size 2276 kBChecksum SHA-512
d61dce77725501d1d2139c28219f3c42e091cba3ddd0dd2d32759b6010a2a21f6578b55e3f259cb8e1bbab9f938104bb378f020bcaf5e988e83ce50deb710d66
Type fulltextMimetype application/pdf

By organisation
Department of Building, Energy and Environmental Engineering
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 1007 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1618 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf