hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Computer simulations of temperature and flow field in industrial spaces using confluent jets air supply method
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering.
2012 (English)Independent thesis Advanced level (degree of Master (One Year)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Ventilation systems are closely connected to indoor environment. In industrial spaces it has a major impact due to air quality and thermal comfort requirements, which leads into health and economy improvements.

Confluent jets ventilation system has been assess in Söderhamn Eriksson, a machinery company located in Mariannelund, Sweden, since it has been proved as the best ventilation performance. Moreover this system is worthy for both heating and cooling purposes, although just heating case will be developed in this thesis.

By means of modelling software such as Gambit and Airpak, the company’s case could have been analyzed via Computational Fluid Dynamics (CFD) software, i.e. Fluent. The analyzed models were accepted after a thorough study of meshing parameters, bearing in mind computational limitations.

Every temperature data gathered from simulation results has been verified with infrared camera figures taken at the company, thus contributing to reach reliable conclusions. As it is inferred from previous papers and empiric theory, the flow field observed is also justified. Then, thermal comfort and air quality analysis relies on consistent facts.

It has been found that current ventilation at the company is slightly misadjusted, since supplied air’s temperature and velocity are slightly off point. Therefore, it is recommended to reduce these values to reach better working environment.

Place, publisher, year, edition, pages
2012. , p. 211
Keywords [en]
HVAC, confluent jets, industrial ventilation, CFD, fluent, gambit, airpak.
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:hig:diva-12409Archive number: TEX 120414OAI: oai:DiVA.org:hig-12409DiVA, id: diva2:540669
Educational program
Energy systems – master’s programme (one year) (swe or eng)
Uppsok
Technology
Supervisors
Examiners
Available from: 2013-04-04 Created: 2012-07-10 Last updated: 2013-04-04Bibliographically approved

Open Access in DiVA

fulltext(7535 kB)719 downloads
File information
File name FULLTEXT01.pdfFile size 7535 kBChecksum SHA-512
027bed604ba003cc2368ddeda05332b923e8adb3608b8289ab3b01d77ff56342d84415522b1f7a0ec8930c5b1cf2d7d78deb60ae8376a9ad8e129b4d7009f993
Type fulltextMimetype application/pdf

By organisation
Department of Building, Energy and Environmental Engineering
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 725 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 468 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf