Cold tap water usage for a chilling system
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering.
2014 (English)Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Both the increasing demand for comfort levels and growth in population are facts that assure that the energy demand in buildings will keep growing in the future. Heating, ventilation and air conditioning systems (HVAC systems) are the principal users of this total energy demand, where percentages over 50% have been reached. Air conditioning is essential to maintain the thermal comfort inside the buildings, and for this reason, innovative cooling systems should be analysed in order to reduce and improve energy usage of these systems.

 

The aim of this thesis is to explore the viability and limitations of a new chilling system that uses tap water as a cooling source. The project has been focused on a building owned by an insurance company in Gävle, where a cooling system has been designed to satisfy the cooling need for an extremely hot day in summer. Water is taken from the main pipe and, via a heat exchanger, it absorbs heat from the chilling circuit. The destination of the tap water, once has been used, has been discussed proposing 3 different options: deliver it to the waste, bring it back to the tap water network and reuse it for hot tap water. Later, based on the results, an overview of the system has been done pointing out the weak and strong parts.

 

When implementing this new system it has to be taken into account that cooling capacity is limited and extra requisites and limitations have to be accomplished since drinking water is used. The most energy efficient design is reusing the water for hot tap water use, since less heat will be needed to warm it up. However, if water is wanted to be reused it should not exceed 15  in order to avoid an environment where legionella could grow and become a health human threat.

A suitable situation for this system would be for building which needs cooling and has a high hot tap water demand. 

Place, publisher, year, edition, pages
2014.
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:hig:diva-17415OAI: oai:DiVA.org:hig-17415DiVA, id: diva2:740750
Supervisors
Examiners
Available from: 2014-08-26 Created: 2014-08-26 Last updated: 2014-08-26Bibliographically approved

Open Access in DiVA

fulltext(13606 kB)688 downloads
File information
File name FULLTEXT01.pdfFile size 13606 kBChecksum SHA-512
0645a531f77a9797fe25a68ffb6936f112f3e45514bde54aeaea7f59db6ce81d7c4bf2b3a2bb5634e9091b27d09f8a18eb65080d6e83eddc3148dcdb5e67faa7
Type fulltextMimetype application/pdf

By organisation
Department of Building, Energy and Environmental Engineering
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 688 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 450 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf