EVALUATION OF HEAT LOSSES FROM ADOMESTIC HOT WATER CIRCULATIONSYSTEM
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering.
2015 (English)Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Heat losses are an important problem in domestic hot water circulation systems. Therefore, toreduce these losses becomes an issue of utmost importance both economically andenvironmentally. Nevertheless, it has not been until recent years when these losses have beenstudied further. Commonly studies have focused on the heat space system operation or radiatorsystem. This study focuses on heat losses in the domestic hot water circulation through thepiping system in a building at a school located in Gävle (Sweden) using non-destructive flowand temperature reading devices. The heat used by the school is provided by the district heatingnetwork that feeds several heat exchangers. The heat losses, at the same time, will be comparedwith simulation and theoretical procedures to corroborate them. The domestic hot water pipingsystem of this study consists on more than 1200 meters of insulated copper pipes with differentdiameters and different insulation thickness. The system was measured for one week (April 26,2015 to May 3, 2015) when there are working days and nonworking days. A 5% of the annualdistrict heating consumption in the school was calculated as heat losses in the domestic hotwater circulation system in the building studied. Finally, improvements in insulation system andchanges in the domestic hot water temperature have been simulated and they demonstrate thatsavings of up to 35% of the heat losses can be achieved and produce significant energy savings.

Place, publisher, year, edition, pages
2015. , p. 60
Keywords [en]
Heat losses, pipes, piping system, circulation, hot water
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-20044OAI: oai:DiVA.org:hig-20044DiVA, id: diva2:842736
Subject / course
Energy systems
Educational program
Energy systems – master’s programme (one year) (swe or eng)
Supervisors
Examiners
Available from: 2015-07-22 Created: 2015-07-22 Last updated: 2015-07-22Bibliographically approved

Open Access in DiVA

EVALUATION OF HEAT LOSSES FROM A DOMESTIC HOT WATER CIRCULATION SYSTEM(1603 kB)3739 downloads
File information
File name FULLTEXT01.pdfFile size 1603 kBChecksum SHA-512
c99b41b48a51d571b89fdc6cb8cda3be713dfa55e87e92c6d0e21dbbb9e9e202d4a4239edd3f4b46faec9d6740e4075b9a8a98c6537bb28c5181ea9c885eea06
Type fulltextMimetype application/pdf

By organisation
Department of Building, Energy and Environmental Engineering
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 3744 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 366 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf