Förbättrad ventilationseffektivitet för Gefleortens mejeri
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering.
2015 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

I detta arbete utfördes en kartläggning av Gefleortens Mejeris ventilationssystem. Syftet med arbetet var att skapa ett energieffektivt ventilationssystem på mejeriet genom att utarbeta konkreta förslag på effektiviseringsmöjligheter som kunde ge ekonomisk avkastning för företaget. För företaget innebär energibesparingar minskade kostnader samtidigt som det krävs mindre resursanvändning, vilket är bra för miljön. För att genomföra effektiviseringar behövdes effektiviseringsstrategier som togs fram genom en litteraturstudie. Systemet behövde kartläggas innan effektiviseringsstrategierna kunde implementeras för att de bästa möjligheterna för byggnaden skulle kunna skapas. Mejeriet har flertalet separata ventilationssystem som försörjer olika delar av byggnaden. I utvalda delar av systemet genomfördes mätningar av flöde och temperaturer.

Tre tilluftssystem valdes ut där effektiviseringsstrategier undersöktes. Systemens flöden mättes med mätinstrument och därefter beräknades till vilka investeringarna var lönsamma. Resultatet visade att det fanns stora besparingsmöjligheter för system TA1 där 211 MWh kunde sparas. Undersökta åtgärder för TA7 blev ej lönsamma. Ett övertryck i ett källarrum behövde åtgärdas genom att skapa ett undertryck i rummet, detta för att undvika att luft i rummet skulle ha möjlighet att sprida sig i byggnaden. Slutsatserna av detta arbete blev att företaget bör implementera åtgärd 1 och 3.

Abstract [en]

This dissertation is an energy survey of Gefleortens Mejeriförening´s HVAC-system. The aim is to create an energy efficient HVAC-system by making proposals of possible energy savings. Energy savings leads to decreased costs for the company and less impact on the environment. To be able to carry out efficiency proposals there was a need for energy saving strategies, which has been obtained through a literature review. Before the efficiency strategies could be examined and proposed the system needed to be surveyed. The dairy production building has several ventilation systems that supplies different parts of the building. In chosen parts of the system measurements of flows and temperatures were conducted.

Three supply air systems were selected to be examined for energy savings. These systems were measured and calculated. The result showed that there were great saving potential for one of the systems, TA1, where 211 MWh could be saved. The examined actions for TA7 was not profitable. A room in the basement had an overpressure that needed to be corrected to an underpressure to avoid that air from that room have the possibility to spread throughout the building. The conclusion of this work is that the company should implement action 1 and 3.

Place, publisher, year, edition, pages
2015. , p. 41
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-20320OAI: oai:DiVA.org:hig-20320DiVA, id: diva2:855987
Subject / course
Energy systems
Educational program
Högskoleingenjör
Supervisors
Examiners
Available from: 2015-09-23 Created: 2015-09-22 Last updated: 2015-09-23Bibliographically approved

Open Access in DiVA

fulltext(1530 kB)327 downloads
File information
File name FULLTEXT01.pdfFile size 1530 kBChecksum SHA-512
533d1aebd85ef7c65e077b9b93467ac950b3e0507ba988b34ac6b1c027db21588499aa2511b24b1da0878fd3897cf4538b2f4005930d9d17c2d8c1e45dc3b82d
Type fulltextMimetype application/pdf

By organisation
Department of Building, Energy and Environmental Engineering
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 327 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 353 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf