hig.sePublications
Change search
Refine search result
1 - 1 of 1
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the Create feeds function.
  • 1.
    Prado, Ana
    University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science.
    Comparing the performance of a combined confluent jets, windows façade supply device and active chilled beam air distribution systems in an office2019Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE creditsStudent thesis
    Abstract [en]

    As temperatures rise around the world and people work more hours throughout the day, the necessity for a comfortable work environment and better thermal comfort has increased. Ventilation systems might have an impact on workers’ health in relation to providing suitable levels of indoor air quality and thermal comfort. Thereby, the purpose of this research was to test different existing installations in an office by taking measures and carrying out a questionnaire to the office staff, so the performance of the systems and the thermal comfort provided could be evaluated. The investigated systems were: wall confluent jets supply device, windows façade supply device and active chilled beams.

    The results show that the mean room temperature from both confluent jets ventilation (CJV) and façade-integrated displacement ventilation (FIDV) is higher than with the mixing ventilation with active chilled beams. Also the maximum temperature difference between neck level and ankle level was lower with the active chilled beams (ACB) system. Nevertheless, the draught rate was higher for the chilled beams. In addition to the fact that the mixing ventilation (MV) systems have the drawback of mixing contaminated air with the fresh air supplied, which can lead to lower performance and diseases for the occupants.

    For the office studied, results confirm that the CJV provides better overall ventilation performance than the mixing and displacement supply devices used in this study, as it combines the positive effects of both mixing and stratification principles.

1 - 1 of 1
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf