hig.sePublikasjoner
Endre søk
Begrens søket
1 - 2 of 2
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Treff pr side
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sortering
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Disputationsdatum (tidligste først)
  • Disputationsdatum (siste først)
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Disputationsdatum (tidligste først)
  • Disputationsdatum (siste først)
Merk
Maxantalet träffar du kan exportera från sökgränssnittet är 250. Vid större uttag använd dig av utsökningar.
  • 1.
    Lidberg, T.
    et al.
    School of Technology and Business Studies, Dalarna University, Falun, Sweden.
    Olofsson, T.
    School of Technology and Business Studies, Dalarna University, Falun, Sweden; Department of Applied Physics and Electronics, Umeå University, Umeå, Sweden.
    Trygg, Louise
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem. Department of Management and Engineering, Linköping University, Linköping, Sweden.
    System impact of energy efficient building refurbishment within a district heated region2016Inngår i: Energy, ISSN 0360-5442, E-ISSN 1873-6785, Vol. 106, s. 45-53Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The energy efficiency of the European building stock needs to be increased in order to fulfill the climate goals of the European Union. To be able to evaluate the impact of energy efficient refurbishment in matters of greenhouse gas emissions, it is necessary to apply a system perspective where not only the building but also the surrounding energy system is taken into consideration. This study examines the impact that energy efficient refurbishment of multi-family buildings has on the district heating and the electricity production. It also investigates the impact on electricity utilization and emissions of greenhouse gases. The results from the simulation of four energy efficiency building refurbishment packages were used to evaluate the impact on the district heating system. The packages were chosen to show the difference between refurbishment actions that increase the use of electricity when lowering the heat demand, and actions that lower the heat demand without increasing the electricity use. The energy system cost optimization modeling tool MODEST (Model for Optimization of Dynamic Energy Systems with Time-Dependent Components and Boundary Conditions) was used. When comparing two refurbishment packages with the same annual district heating use, this study shows that a package including changes in the building envelope decreases the greenhouse gas emissions more than a package including ventilation measures.

  • 2.
    Lidberg, Tina
    et al.
    Högskolan Dalarna.
    Swing Gustafsson, Moa
    Högskolan Dalarna; KTH.
    Myhren, Jonn Are
    Högskolan Dalarna.
    Olofsson, Thomas
    Högskolan Dalarna; Umeå universitet.
    Trygg, Louise
    Linköpings universitet.
    Comparing different building energy efficiency refurbishment packages performed within different district heating systems2017Inngår i: Energy Procedia, ISSN 1876-6102, E-ISSN 1876-6102, Vol. 105, s. 1719-1724Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    This study analyses the differences in primary energy (PE) use of a multi-family building refurbished with different refurbishment packages situated in different district heating systems (DHS). Four models of typical DHS are defined to represent the Swedish DH sector. The refurbishment packages are chosen to represent typical, yet innovative ways to improve the energy efficiency of a representative multi-family building in Sweden. The study was made from a broad system perspective, including valuation of changes in electricity use on the margin. The results show a significant difference in PE savings for the different refurbishment packages, depending on both the package itself as well as the type of DHS. Also, the package giving the lowest specific energy use per m2 was not the one which saved the most PE. © 2017 The Authors.

1 - 2 of 2
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf