hig.sePublikasjoner
Endre søk
Begrens søket
1 - 4 of 4
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Treff pr side
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sortering
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Disputationsdatum (tidligste først)
  • Disputationsdatum (siste først)
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Disputationsdatum (tidligste først)
  • Disputationsdatum (siste først)
Merk
Maxantalet träffar du kan exportera från sökgränssnittet är 250. Vid större uttag använd dig av utsökningar.
  • 1.
    Lundström, Hans
    Högskolan i Gävle, Akademin för teknik och miljö, BMG-labbet.
    Improving long-term stability of hot-wire anemometer sensors by means of annealing2015Inngår i: Review of Scientific Instruments, ISSN 0034-6748, E-ISSN 1089-7623, Vol. 86, nr 8, artikkel-id 086104Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Annealing procedures for hot-wire sensors of platinum and platinum-plated tungsten have been investigated experimentally. It was discovered that the two investigated sensor metals behave quite differently during the annealing process, but for both types annealing may improve long-term stability considerably. Measured drift of sensors both without and with prior annealing is presented. Suggestions for suitable annealing temperatures and times are given. 

  • 2.
    Lundström, Hans
    et al.
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för byggnadsteknik, energisystem och miljövetenskap, Energisystem och byggnadsteknik.
    Mattsson, Magnus
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för byggnadsteknik, energisystem och miljövetenskap, Energisystem och byggnadsteknik.
    Radiation influence on indoor air temperature sensors: Experimental evaluation of measurement errors and improvement methods2020Inngår i: Experimental Thermal and Fluid Science, ISSN 0894-1777, E-ISSN 1879-2286, Vol. 115, artikkel-id 110082Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Radiation influence on commonly used temperature sensors for measuring indoor air temperatures can be significant, especially at the typically low air velocities occurring indoors. Conceptually, a physical sensor may not read the true air temperature, it only reads its own temperature, and, being a solid body, it will exchange energy with the surrounding surfaces (walls, windows etc.) through radiation. In the present study, radiation influence on indoor air temperature measurements was investigated experimentally and errors were quantified in simple terms. Measures to reduce the impact on some common temperature sensors were explored. A special test rig was built to simulate typical airflow and radiation environments indoors. It is suggested that the radiation impact on a temperature sensor is quantified by a radiation sensitivity factor defined as RSF = hrad/hconv, where hrad and hconv are heat transfer coefficients for radiation and convection, respectively. As this definition infers, the radiation sensitivity is dependent on size, geometry and emissivity of the temperature sensor. The radiation sensitivity factor, thus being unique for each type of sensor, was measured for some common types of thermistors and thermocouples. It is demonstrated that radiation errors may be reduced by 60 – 80 % on thermistors by reducing their emissivity through gold sputtering, and on thermocouples by stripping the insulation at the outermost part of their sensor leads.

  • 3.
    Lundström, Hans
    et al.
    Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö.
    Sandberg, Mats
    Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö.
    Moshfegh, Bahram
    Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för energi- och maskinteknik.
    Temperature dependence of convective heat transfer from fine wires in air: a comprehensive experimental investigation with application to temperature compensation in hot-wire anemometry2007Inngår i: Experimental Thermal and Fluid Science, ISSN 0894-1777, E-ISSN 1879-2286, Vol. 32, nr 2, s. 649-657Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Heat transfer from a fine wire to air has been experimentally investigated. High accuracy measurements, where both the air temperature and wire temperature have been varied systematically and independently have made it possible to map the behavior of the heat transfer process for different velocities, air temperatures, and wire temperatures. Based on these results a compensation method is proposed which makes it possible to temperature compensate hot wires of large aspect ratio and at low Reynolds numbers for anemometry measurements with velocity calibration only at one air temperature.

  • 4.
    Sandberg, Mats
    et al.
    Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö.
    Lundström, Hans
    Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö.
    Nilsson, Håkan
    Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö.
    Stymne, Hans
    Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö.
    Experimental methods in ventilation2008Inngår i: Advances in building energy research, ISSN 1751-2549, Vol. 2, s. 159-210Artikkel i tidsskrift (Fagfellevurdert)
1 - 4 of 4
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf