hig.sePublikationer
Ändra sökning
Avgränsa sökresultatet
1 - 10 av 10
RefereraExporteraLänk till träfflistan
Permanent länk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Träffar per sida
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sortering
  • Standard (Relevans)
  • Författare A-Ö
  • Författare Ö-A
  • Titel A-Ö
  • Titel Ö-A
  • Publikationstyp A-Ö
  • Publikationstyp Ö-A
  • Äldst först
  • Nyast först
  • Skapad (Äldst först)
  • Skapad (Nyast först)
  • Senast uppdaterad (Äldst först)
  • Senast uppdaterad (Nyast först)
  • Disputationsdatum (tidigaste först)
  • Disputationsdatum (senaste först)
  • Standard (Relevans)
  • Författare A-Ö
  • Författare Ö-A
  • Titel A-Ö
  • Titel Ö-A
  • Publikationstyp A-Ö
  • Publikationstyp Ö-A
  • Äldst först
  • Nyast först
  • Skapad (Äldst först)
  • Skapad (Nyast först)
  • Senast uppdaterad (Äldst först)
  • Senast uppdaterad (Nyast först)
  • Disputationsdatum (tidigaste först)
  • Disputationsdatum (senaste först)
Markera
Maxantalet träffar du kan exportera från sökgränssnittet är 250. Vid större uttag använd dig av utsökningar.
  • 1.
    Contero, Francisco
    et al.
    University of Zaragoza.
    Gomes, João
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Gustafsson, Mattias
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Karlsson, Björn O.
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    The impact of shading in the performance of threee different solar PV systems2016Konferensbidrag (Refereegranskat)
  • 2.
    Francisco Contero, Jose
    et al.
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem. University of Zaragoza.
    Gomes, João
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Gustafsson, Mattias
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Karlsson, Björn O.
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    The impact of shading in the performance of three different solar PV systems2017Ingår i: PROCEEDINGS OF THE 11TH ISES EUROSUN 2016 CONFERENCE, INTL SOLAR ENERGY SOC , 2017, s. 1168-1179Konferensbidrag (Refereegranskat)
    Abstract [en]

    Partial shading decreases the performance of PV modules due to the series connection between the solar cells. In the recent years, several new technologies have emerged within the photovoltaics field to mitigate the effect of shading in the performance of the PV modules. For an accurate assessment of the performance of these devices, it is required to evaluate them comparatively in different circumstances. Three systems with six series-connected PV modules (each containing 60 cells) have been installed at the University of Gavle. System One comprises a string inverter system with 6 PV modules; System Two features a DC-DC optimizer per panel and a string inverter; System Three incorporates three micro inverters for six modules. A major conclusion of this study was that under partial shading of one (or more) modules both System Two (DC-DC optimizers) and System Three (micro inverters) perform considerably better than System One (string inverter), as long as the Impp of the shadowed module is lower than the Impp of the unshaded string It is also important that the Vmpp in the shaded module is higher than the lowest allowed voltage of the DC-DC optimizer or module inverter. The economic implications of the usage of these devices were also analyzed.

  • 3.
    Gustafsson, Mattias
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Challenges for decision makers when feed in tariffs or net metering schemes change to incentives dependent of a high share of self-consumed electricity2017Ingår i: 2017 IEEE 44th Photovoltaic Specialist Conference (PVSC), IEEE conference proceedings, 2017, s. 2025-2030Konferensbidrag (Refereegranskat)
    Abstract [en]

    When there are differences in economic value of self-consumed and exported electricity, profitable PV installations are dependent on accurate predictions of self-consumed electricity. In this study, minute-based data of PV production and electricity use were logged in a single-family house in Sweden. It is shown that when self-consumed electricity is measured, a low time resolution and different electric meter configurations can result in 60% lower registered self-consumed electricity than predicted. When feed-in tariffs or net metering schemes change to incentives dependent on the fraction of self-consumed electricity, the market and electric meter infrastructure must be prepared to avoid market disturbances.

  • 4.
    Gustafsson, Mattias
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem. Gävle Energi, Gävle, Sweden.
    Effects of different time resolution when self-consumed and produced excess electricity is predicted in a single family house: case study in cold climate, Sweden2016Konferensbidrag (Refereegranskat)
  • 5.
    Gustafsson, Mattias
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Energy efficiency measures in the built environment - some aspects to consider in Sweden2018Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
    Abstract [sv]

    Sammanfattning Det traditionella energisystem som vi är vana vid idag kommer att förändras i framtiden. Oron för växthuseffekten och dess konsekvenser medför att olika åtgärder genomförs, framförallt för att minska koldioxidutsläppen från fossila bränslen.

    I denna avhandling har flerfamiljshus simulerats med avseende på energi-användningen när olika energieffektiviseringsåtgärder implementeras. Resultatet av förändringarna i globala koldioxidutsläpp har sedan beräknats för de olika energieffektiviseringsåtgärderna. De simulerade resultaten har även använts för att analysera hur en byggnads energieffektivitet enligt Boverkets byggregler varierar med olika uppvärmningssätt och om byggnaden har en solvärme- eller solcellsanläggning installerad.

    Denna avhandling visar att värmepumpar favoriseras jämfört med användning av fjärrvärme när en fastighets energieffektivitet beräknas enligt Boverkets byggregler. Samtidigt visas att den viktigaste åtgärden för att minska de globala koldioxidutsläppen är att minska elanvändningen eller att öka elproduktionen lokalt inom det studerade fjärrvärmeområdet.

    Avhandlingen undersöker också hur konfigureringen av kundens elmätare i elnätet påverkar den uppmätta andelen egenanvänd och överproducerad el. Slutligen har fyra lokala lågvoltsnät simulerats då ett framtida scenario för laddning av elfordon adderats till fastigheternas nuvarande elanvändning.

    Resultaten visar att om en villafastighet installerar en solcellsanläggning så påverkar konfigureringen av kundens elmätare den uppmätta andelen egenanvänd och överproducerad el och skillnaden kan vara relativt stor. Avhandlingen visar också att delar av lågvoltselnätet klarar en stor andel elfordon och en hög andel solcellsanläggningar men att landsbygdsnätet behöver förstärkas för att klara den ökade lasten i de antagna scenarierna.

  • 6.
    Gustafsson, Mattias
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Evaluation of energy conserving measures in buildings connected to a district heating system: case studies in Gävle, Sweden2016Licentiatavhandling, sammanläggning (Övrigt vetenskapligt)
    Abstract [en]

    When different energy conserving measures are implemented for reducing energy use in buildings and the buildings are connected to district heating systems, it is important that an overall system analysis is made which takes into account the effects of total change of energy use due to the energy conserving measures.

    The method applied in this thesis uses hourly production data for the different production units in the district heating system in Gävle, Sweden. The merit order of the different production units is dependent on the electricity spot market price. To calculate the merit order, hourly data for the electricity price is used. The marginal production unit can then be determined for each hour of the investigated year.

    This thesis analyzes five different energy conserving measures in a multi-dwelling building regarding how they affect the marginal production units in the district heating system. For CO2 emission evaluations, two different combinations of heat and electricity conserving measures are compared to installation of an exhaust air heat pump. This thesis also analyzes how the configuration of the electric meter affects the measured amount of self-consumed and produced excess electricity for a single-family house and for two multi-dwelling buildings of different sizes.

    The results show that the use of electricity is the most important objective to consider. The increased use of electricity for operation of the heat pump contributes to an increase of global CO2 emissions and the electricity produced by the solar photovoltaic installation contributes to a decrease of global CO2 emissions.

    The results also show that the configuration of the electric meter is important for the single-family house but negligible for the multi-dwelling buildings. The amount of produced excess electricity is high for all buildings, which means that the economic value of produced excess electricity is important for a profitable installation.

  • 7.
    Gustafsson, Mattias
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Impacts of different electric vehicle charging strategies on low voltage distribution networks, a case study for SwedenManuskript (preprint) (Övrigt vetenskapligt)
  • 8.
    Gustafsson, Mattias
    et al.
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem. Gävle Energi AB, Gävle, Sweden.
    Karlsson, Björn
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Rönnelid, Mats
    Högskolan Dalarna.
    How the electric meter configuration affect the monitored amount of self-consumed and produced excess electricity from PV systems: case study in Sweden2017Ingår i: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 138, s. 60-68Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    This study evaluates how the principal function of bi-directional electric meters affects the monitored amount of self-consumed and produced excess electricity for dwelling buildings connected to the grid by three phases. The electric meters momentarily record the sum of the phases or the phases individually and then summarize the recorded values to a suitable time period and is then collected by the grid owner. In Sweden, both electric meter configurations fulfill laws and regulations.

    The meter configuration affects the monitored distribution of self-consumed and produced excess electricity significantly for the investigated single-family house but is negligible for the investigated multi-dwelling buildings. The monitored self-consumed electricity produced by the PV installation for the single-family house varies between 24% and 55% depending on the configuration and how the inverter is installed for the investigated year. The difference in economic value for the produced electricity varies between 79.3 to 142 Euros.

    Due to the electric meter configuration, the profitability of PV systems will be different for identical single-family houses with identical conditions. This should be corrected for a well-functioning market. It is also important to decide how the configuration should be designed to ensure that different incentives and enablers results in desired effects.

  • 9.
    Gustafsson, Mattias
    et al.
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem. Gävle Energi AB, Gävle, Sweden .
    Rönnelid, Mats
    Energy Technology, Högskolan Dalarna, Falun, Sweden.
    Trygg, Louise
    Linköpings universitet.
    Karlsson, Björn
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    CO2 emission evaluation of energy conserving measures in buildings connected to a district heating system: case study of a multi-dwelling building in Sweden2016Ingår i: Energy, ISSN 0360-5442, E-ISSN 1873-6785, Vol. 111, s. 341-350Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    When taking action to fulfill the directives from the European Union, energy conserving measures will be implemented in the building sector. If buildings are connected to district heating systems, a reduced heat demand will influence the electricity production if the reduced heat demand is covered by combined heat and power plants.

    This study analyze five different energy conserving measures in a multi-dwelling building regarding how they affect the marginal production units in the district heating system in Gävle, Sweden. For CO2 emission evaluations, two different combinations of heat and electricity conserving measures are compared to an installation of an exhaust air heat pump.

    The different energy conserving measures affect the district heating system in different ways. The results show that installing an exhaust air heat pump affects the use/production of electricity in the district heating system most and electricity conserving measures result in reduced use of electricity in the building, reduced use of electricity for production of heat in the district heating system and an increase of electricity production.

    The conclusion is that electricity use in the building is the most important factor to consider when energy conserving measures are introduced in buildings within the district heating system in Gävle.

  • 10.
    Gustafsson, Mattias
    et al.
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Thygesen, Richard
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Karlsson, Björn
    Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
    Ödlund, Louise
    Division of Energy Systems, Department of Management and Engineering, Linköping University, Linköping, Sweden.
    Rev-Changes in Primary Energy Use and CO2 Emissions: An Impact Assessment for a Building with Focus on the Swedish Proposal for Nearly Zero Energy Buildings2017Ingår i: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 10, nr 7, artikel-id 978Artikel i tidskrift (Refereegranskat)
    Abstract [en]

    In the European Union's Energy Performance of Buildings Directive, the energy efficiency goal for buildings is set in terms of primary energy use. In the proposal from the National Board of Housing, Building, and Planning, for nearly zero energy buildings in Sweden, the use of primary energy is expressed as a primary energy number calculated with given primary energy factors. In this article, a multi-dwelling building is simulated and the difference in the primary energy number is investigated when the building uses heat from district heating systems or from heat pumps, alone or combined with solar thermal or solar photovoltaic systems. It is also investigated how the global CO2 emissions are influenced by the different energy system combinations and with different fuels used. It is concluded that the calculated primary energy number is lower for heat pump systems, but the global CO2 emissions are lowest when district heating uses mostly biofuels and is combined with solar PV systems. The difference is up to 140 tonnes/year. If the aim with the Swedish building code is to decrease the global CO2 emissions then the ratio between the primary energy factors for electricity and heat should be larger than three and considerably higher than today.

1 - 10 av 10
RefereraExporteraLänk till träfflistan
Permanent länk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf