Energy Audit in Educational Buildings: Case study of Fridhemsskolan in Gävle
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
2017 (engelsk)Independent thesis Advanced level (degree of Master (One Year)), 10 poäng / 15 hpOppgave
Abstract [en]

The global share from buildings towards energy usage in residential and commercial buildings have been increasing constantly reaching between 20% to 40% in developed countries and has overtook the other major sectors: industrial and transportation. Energy demand reduction in the building sector is important for Sweden to achieve national energy aims for reduced energy use in the future.  For this reason, energy efficiency measures in buildings today is one of the main objective for energy policy towards 2020 goals.

 

This project moves on the same path to find energy efficiency potential in Fridhemsskolan buildings in Gävle, Sweden by performing energy audit using IDA-ICE software to simulate energy performance for the buildings under study. In addition, measurements have been made on three of the school buildings named Hus 1, Hus 2 and Hus 3.

 

The results include different energy efficiency retrofits on each building and economic analysis of these retrofits for each building individually and for the whole buildings together. The presented measures are reducing working hours of the ventilation system in Hus 2, change of CAV system with VAV system in (Hus 1 and Hus 2) and lights changing to LED, s efficient lights and building envelope improvement which includes walls and roof extra insulation and windows replacement.

 

Replacement of the CAV system in Hus 1 and Hus 2 were not economically beneficial when considering their high cost compared to energy reduction that can be achieved by applying them. On the other hand, energy retrofits analysis showed that combination of the following energy efficiency measures is the most effective and profitable: extra insulation (walls and roof), windows replacement and lights change to LED in the three buildings. In addition to these measure is reducing running hours of the ventilation system in Hus 2.

 

Implementation of the recommended energy efficiency measures will save 120, 737 kWh/ year of the district heating and 21, 962 kWh/year electricity consumption with capital investment of 417, 396 SEK and 98, 957 SEK/ year cost saving with payback period of 4.2 years. These figures represent 40.3% and 18.1% reduction in district heating and electricity energy use respectively.

 

Since reducing working hours of ventilation system measure has no capital investment and have the highest figure of energy reduction it reduces payback period significantly. In case the amount of money saved by this measure doesn’t consider; payback period for the other measures which require capital investment will be 13.5 years and the energy saving in terms of cost will be 30, 874 SEK/ year. 

sted, utgiver, år, opplag, sider
2017. , s. 64
Emneord [en]
energy audit, building energy performance, energy retrofits technology, energy efficiency measures in building, IDA-ICE
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-25191OAI: oai:DiVA.org:hig-25191DiVA, id: diva2:1139939
Fag / kurs
Energy systems
Utdanningsprogram
Energy systems – master’s programme (one year) (swe or eng)
Presentation
2017-08-16, 11:215, Gävle, 11:00 (engelsk)
Veileder
Examiner
Tilgjengelig fra: 2017-09-21 Laget: 2017-09-10 Sist oppdatert: 2017-09-21bibliografisk kontrollert

Open Access i DiVA

fulltext(5245 kB)750 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 5245 kBChecksum SHA-512
0984599f499ee93e8b855be11dcc060bc3269c9605c21a7bb4833352d49df95c6084e98841031c878426037282ebd59e5b56b769cb0af6e71b755d611aebcc4e
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Abdalla Mohamed Ahmed, Fayad
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 750 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1459 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf