Parametric study of energy retrofit options for a historical building
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för byggnadsteknik, energisystem och miljövetenskap, Energisystem och byggnadsteknik.
2022 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
Hållbar utveckling
Uppsatsen/examensarbetet har inslag av hållbar utveckling enligt högskolans kriterier
Abstract [en]

Retrofitting measures in old buildings aimed at reducing energy consumption has become a widespread subject and an urgent matter to counteract the effects of climate change and GHGs emissions. The globe has reaffirmed its agreement taken in COP21 to reduce emissions in COP26. The building sector is one of the culprits with a 70 % future energy consumption forecasted by 2050 i.e., the year certain countries aim to carbon neutral (e.g., Sweden). An old building with a severe problem of energy leakage has been studied under the influence of multiple parameters such as building orientation, shading systems, location, Low-E film and an alternative energy supply (GHP). The original building’s EnU amounted to 194.5 kWh/m2•yr; the parameters were applied and orientation of 90⁰ worked best, if the building was being designed, contrary to this case. However, energy reductions, compared to the base model, were actually achieved with the application of Low-E (5%) films and when substituting the heating demand with a GHP (57.5%), LEF-GHP reached (59.2%) and a corresponding decrease in CO2 emissions. Thermal comfort was best achieved with models that had the highest energy consumption such as LEF and ES making it counterproductive in fulfilling the aim of reducing GHG footprint of Rådhuset. The economic feasibility study showed that the installation of a GHP with at least the COP of 4.0 would lead to a shorter payback period than solely applying LEF. A tailored solution of a change in the energy source such as electrified heat supply from renewables combined with LEFs would reduce the energy and emission impact of any building; this would help the building sector reach the envisioned goal of carbon neutrality in 2050.

sted, utgiver, år, opplag, sider
2022. , s. 58
Emneord [en]
Energy Retrofitting, Building Performance, Thermal Comfort, Shading, Building Orientation, Location, Low-E films, Solar Gains
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-39987OAI: oai:DiVA.org:hig-39987DiVA, id: diva2:1699424
Fag / kurs
Energy systems
Utdanningsprogram
Energy systems – master’s programme (two years)
Veileder
Examiner
Tilgjengelig fra: 2022-09-28 Laget: 2022-09-27 Sist oppdatert: 2025-10-02bibliografisk kontrollert

Open Access i DiVA

Thesis(2470 kB)272 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2470 kBChecksum SHA-512
94a9063cc3d3bdae39d3838f23f2f451419b32b818fb945d4459015c01a66bd9dd166dd00bfeb5d3131518e35d088307633abc136856d4210985a274ec344d3c
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 273 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 425 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf