hig.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Local tracer emission mimicking air-borne disease spreading in an office space with mixing ventilation
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för elektroteknik, matematik och naturvetenskap, Kemi.ORCID-id: 0000-0002-8985-2562
2025 (engelsk)Inngår i: Healthy Buildings 2025. REYKJAVÍK, ICELAND, June 8-11 2025: SHAPING THE FUTURE WITH SUSTAINABLE  &  HEALTHY BUILDINGS, 2025, s. 8-, artikkel-id 299Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

In a laboratory office setting with four occupants facing the walls, local emission of a tracer gas (B) in the breathing zone of one infected occupant mimics the transmission of an air-borne disease. At the same time, another tracer gas (A) is homogeneously emitted in the office space so that the local mean age can be determined in each sampling point. Tracers are passively collected in the breathing zones of the occupants and in sixteen sampling positions distributed at four heights. A laboratory office setup with mixing ventilation conditions and a single ceiling exhaust in a corner is investigated. The distribution of B-tracer is analyzed in the sampling points for the four possible locations of an infected occupant in relation to the exhaust location. The results reported are in the absence of thermal plumes, i.e., the manikins representing occupants were turned off. The relative apparent emission rates calculated from the measurements are conjectured to represent the steady state transfer probabilities from the respective breathing zones. As expected, for mixing ventilation conditions, the steady state probabilities to most positions are similar. Nevertheless, the steady state transfer probabilities from the breathing zones of the pair of manikins closer to the exhaust cause slightly more spreading, 0.83 ± 0.04 and 0.82 ± 0.04, than the other pair, 0.76 ± 0.03 and 0.75 ± 0.06.

sted, utgiver, år, opplag, sider
2025. s. 8-, artikkel-id 299
Emneord [en]
air-borne disease transmission, office environment, mixing ventilation, local mean age of air
HSV kategori
Forskningsprogram
Hållbar stadsutveckling
Identifikatorer
URN: urn:nbn:se:hig:diva-48914Scopus ID: 2-s2.0-105023450497OAI: oai:DiVA.org:hig-48914DiVA, id: diva2:2019040
Konferanse
ISIAQ INTERNATIONAL Regional Conference, Europe
Tilgjengelig fra: 2025-12-04 Laget: 2025-12-04 Sist oppdatert: 2025-12-08bibliografisk kontrollert

Open Access i DiVA

fulltext(512 kB)68 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 512 kBChecksum SHA-512
92ebfd43acf9db98f3cfc1e8602de34657eac02bb158f6579b2243f6f6c31860f3b3747823bfdd0be17055017f6e73f3a37e9ce4ab8f31541d30e99886451175
Type fulltextMimetype application/pdf

Scopus

Person

Björling, Mikael

Søk i DiVA

Av forfatter/redaktør
Björling, Mikael
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 70 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1081 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf