Energy Audit in Educational Buildings: Case study of Fridhemsskolan in Gävle
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
2017 (Engelska)Självständigt arbete på avancerad nivå (magisterexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)
Abstract [en]

The global share from buildings towards energy usage in residential and commercial buildings have been increasing constantly reaching between 20% to 40% in developed countries and has overtook the other major sectors: industrial and transportation. Energy demand reduction in the building sector is important for Sweden to achieve national energy aims for reduced energy use in the future.  For this reason, energy efficiency measures in buildings today is one of the main objective for energy policy towards 2020 goals.

 

This project moves on the same path to find energy efficiency potential in Fridhemsskolan buildings in Gävle, Sweden by performing energy audit using IDA-ICE software to simulate energy performance for the buildings under study. In addition, measurements have been made on three of the school buildings named Hus 1, Hus 2 and Hus 3.

 

The results include different energy efficiency retrofits on each building and economic analysis of these retrofits for each building individually and for the whole buildings together. The presented measures are reducing working hours of the ventilation system in Hus 2, change of CAV system with VAV system in (Hus 1 and Hus 2) and lights changing to LED, s efficient lights and building envelope improvement which includes walls and roof extra insulation and windows replacement.

 

Replacement of the CAV system in Hus 1 and Hus 2 were not economically beneficial when considering their high cost compared to energy reduction that can be achieved by applying them. On the other hand, energy retrofits analysis showed that combination of the following energy efficiency measures is the most effective and profitable: extra insulation (walls and roof), windows replacement and lights change to LED in the three buildings. In addition to these measure is reducing running hours of the ventilation system in Hus 2.

 

Implementation of the recommended energy efficiency measures will save 120, 737 kWh/ year of the district heating and 21, 962 kWh/year electricity consumption with capital investment of 417, 396 SEK and 98, 957 SEK/ year cost saving with payback period of 4.2 years. These figures represent 40.3% and 18.1% reduction in district heating and electricity energy use respectively.

 

Since reducing working hours of ventilation system measure has no capital investment and have the highest figure of energy reduction it reduces payback period significantly. In case the amount of money saved by this measure doesn’t consider; payback period for the other measures which require capital investment will be 13.5 years and the energy saving in terms of cost will be 30, 874 SEK/ year. 

Ort, förlag, år, upplaga, sidor
2017. , s. 64
Nyckelord [en]
energy audit, building energy performance, energy retrofits technology, energy efficiency measures in building, IDA-ICE
Nationell ämneskategori
Annan teknik
Identifikatorer
URN: urn:nbn:se:hig:diva-25191OAI: oai:DiVA.org:hig-25191DiVA, id: diva2:1139939
Ämne / kurs
Energisystem
Utbildningsprogram
Energisystem – magisterprogram (sv eller eng)
Presentation
2017-08-16, 11:215, Gävle, 11:00 (Engelska)
Handledare
Examinatorer
Tillgänglig från: 2017-09-21 Skapad: 2017-09-10 Senast uppdaterad: 2017-09-21Bibliografiskt granskad

Open Access i DiVA

fulltext(5245 kB)731 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 5245 kBChecksumma SHA-512
0984599f499ee93e8b855be11dcc060bc3269c9605c21a7bb4833352d49df95c6084e98841031c878426037282ebd59e5b56b769cb0af6e71b755d611aebcc4e
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Abdalla Mohamed Ahmed, Fayad
Av organisationen
Energisystem
Annan teknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 731 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 1322 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf