The effects of low-emissivity window films on thermal comfort and energy performance of a historic stone building in cold climate: computer simulations with "IDA ICE"
2019 (English)Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE credits
Student thesis
Sustainable development
The essay/thesis is mainly on sustainable development according to the University's criteria
Abstract [en]
Low-emissivity (low-E) window films are designed to improve the energy performance of windows and prevent indoor overheating by solar radiation. These films can be applied to different types of glazing units without the need for changing the whole window. This characteristic offers the possibility to improve the energy performance of the window of old and historic buildings for which preservation regulations say windows should remain more or less unchanged. This research aims to figure out to what extent a low-E window film can improve thermal comfort and energy performance of an old three-storey historic stone building in the cold climate of Mid-Sweden. In this research, first, with help of the simulation software “IDA ICE”, the entire building was modelled without window films in a one-year simulation. Second step was to add the low-E window films (3M Thinsulate Climate Control 75 (CC75)) to all the windows and repeat the simulation. Comparison between the results of the two cases revealed an improvement in energy use reduction as well as the thermal comfort when applying the films. For the application of the window films, a cost analysis using payback method was carried out which showed a long- time payback period. Although an investment with a long-time payback period is considered as a disadvantage, for historic buildings with very strict retrofit regulations specially when it comes to the building’s facades, application of the low-emissivity window films for better energy performance and thermal comfort is among the recommendable measures, but not necessarily the best.
Place, publisher, year, edition, pages
2019. , p. 67
Keywords [en]
Low-E window films, low-emissivity window films, thermal comfort, IDA ICE, solar heat gain, U-value, building energy saving measures, heating demand, cooling demand
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-30145OAI: oai:DiVA.org:hig-30145DiVA, id: diva2:1328574
Subject / course
Energy systems
Educational program
Energy systems – master’s programme (one year) (swe or eng)
Presentation
2019-06-04, 91:207, Högskolan i Gävle 801 76, Gävle, 14:08 (English)
Supervisors
Examiners
2019-06-242019-06-212025-10-02Bibliographically approved