KEY FACTORS AND PROBLEMS IN THE PERFORMANCE OF KITCHEN VENTILATION SYSTEMS
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science.
2020 (English)Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Regarding the great importance of a good working environment, in this research, ventilation systems installed in kitchens of restaurants were studied in order to avoid problems and to understand the key factors that can influence on the performance of the system. The results obtained were taken into account to provide some recommendations to a real ventilation system of a restaurant called Pastaria in Gävle (Sweden). This concrete ventilation system was not performing good, and some calculations based on the kitchen design were made trying to offset the problem.

A large number of scientific studies related to restaurant kitchen hoods and ventilation systems were used to get the findings. These articles were obtained from scholar web databases. The main problem found in kitchen hoods is the inadequate exhaust airflow. The minimum required airflow varies depending on the size and shape of the hood. Keil et al. (2004) found in their research that only 39% and 24% of the studied hoods met the minimum recommended airflow from ACGIH and ASHRAE guidelines, respectively. Other key factors found are related to the kitchen design. The kitchen hood is recommended to have incorporated a capture hood covering all the burners. Side panels can be employed to increase the capture and containment. High efficiency filters and rigid ducts are also recommended. The cleaning of the ventilation ducts is also an important factor, they are recommended to be cleaned between 1 to 9 years depending on the activity of the kitchen. Thus, key factors such as disturbing airflows and the presence/movement of the cooks can disturb the kitchen hood performance. A very effective solution, isolating the fumes below the hood, that is getting developed is the installation of an inclined air curtain from the cooking surface.

Related to the kitchen hood and the ventilation system of the Pastaria restaurant. Some measurements and information were obtained in a visit to the restaurant. After calculations, it was obtained based on the kitchen design that is required a minimum airflow of 4 140 m3/hour. In order to do that, the heat exchanger Swegon Silver C RX, installed in the system, requires a minimum size of 11/12. The distribution of the kitchen appliances in this restaurant seems to be correct. However, a future study in order to see if there are disturbing airflows affecting the kitchen hood performance must be carried out. If after checking all recommendations the performance of the kitchen hood is not good enough yet, an inclined air curtain may be installed due to their great effectiveness against problems of hoods.

In conclusion, it was clearly obtained that a correct kitchen distribution design and calculations must be done for each restaurant in order to install the most adequate kitchen hood with the best characteristics. This way, fumes, odors, moisture and particles will be easily exhausted allowing a better environment out of risks to the establishment and customers health.

Place, publisher, year, edition, pages
2020. , p. 48
Keywords [en]
RESTAURANT KITCHEN VENTILATION, KITCHEN HOOD, VENTILATION SYSTEM, AIRFLOW, AIR QUALITY, PRESSURE DROP, HOOD PERFORMANCE, EFFICIENCY
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hig:diva-33362OAI: oai:DiVA.org:hig-33362DiVA, id: diva2:1460011
Educational program
Energy systems – master’s programme (one year) (swe or eng)
Presentation
2020-08-20, 09:30 (English)
Supervisors
Examiners
Available from: 2020-08-25 Created: 2020-08-21 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

fulltext(1424 kB)3558 downloads
File information
File name FULLTEXT01.pdfFile size 1424 kBChecksum SHA-512
5128ae45e3890918dae324b05f8f8d319ea2f006ed3fa821c0f62f02a9ef4ac3774612b9dcca7163f1e97eb96697f809f793925830ee8bfb1c2b850b3ba13d6d
Type fulltextMimetype application/pdf

By organisation
Department of Building Engineering, Energy Systems and Sustainability Science
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 3646 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1856 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf