Perspectives of a climate-neutral urban district: Evaluation of greenhouse gas emissions, exergy and energy balances
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science. (Future heat)
2020 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Sustainable development
The essay/thesis is mainly on sustainable development according to the University's criteria
Abstract [en]

A climate-neutral city can be viewed at in many different aspects. This report investigates the greenhouse gas, exergy and energy balance for both heat pumps and district heat supply at local, national and methane gas perspectives of the energy conversion processes. Through a numerical grey box model of a geographical information system based urban district. There seven different passive-, nearly zero-, and plus-energy residential buildings are implemented. That are developed and annually simulated in the IDA ICE software. There, thermal transmittance and building geometry are the most urgent parameters that impacts the space heating demand and energy performance. They are estimated by current and proposed primary energy weight factors where the geometry shape is undefined, while the altitude impact’s the building's energy, exergy, and greenhouse gas balance. Therefore high-rise building's energy performance are poorer than low-rise buildings, simultaneously as heat pump supply enables higher altitude than district heating. Other energy savings occur through additional energy-efficient technologies, energy generating technologies and soft tools that change residents’ behavior.

The investigated urban district is placed in the Swedish city Gävle, which meets residents’ demand for approximately 6000 apartments without additional service. It is a plus energy district for heat pump supply and passive energy for district heating supply. Although the district heated urban district electricity-saving towards heat pump corresponds to 32 percent of the urban district's total facility and household electricity utilization. The energy analysis include the perspective of the facility’s energy utilization and generation, and the perspectives of residents’ energy utilization and recovery from their waste resource production. This makes the urban district exergy productive and carbon-negative during the operating phase, regardless of emission value and heat supply technology, since the facility perspective compensates for the residents’ electricity utilization and consumption of goods. Therefore, there are no need for tree plantation as compensation of greenhouse gas pollution since the carbon negativity corresponds to between 2 to 154 hectares of forest. The study is therefore relevant for other geographical locations in Sweden depending on geographical location, heat supply technology and emission value from the primary energy conversion processes.

Place, publisher, year, edition, pages
2020. , p. 70
Keywords [en]
Carbon neutral district, energy passive district, sustainable cities, exergy positive district, passive- nearly zero- and plus-energy buildings
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-33382OAI: oai:DiVA.org:hig-33382DiVA, id: diva2:1461611
External cooperation
Gävle Energi; Gävle Kommun
Subject / course
Energy systems
Educational program
Energy systems – master’s programme (two years)
Presentation
2020-05-15, ZOOM, Förrådsgatan 6, Gävle, 10:00 (English)
Supervisors
Examiners
Note

Förstudie i future heat projekt angående Framtidens klimatsmarta stad genom klimatneutral bebyggelse med fjärrvärme.

Available from: 2021-06-15 Created: 2020-08-27 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

fulltext(4594 kB)336 downloads
File information
File name FULLTEXT01.pdfFile size 4594 kBChecksum SHA-512
2e54e0bdba69d44a4c81ba54c6271a5884eabb148f217c48e61a9660761f41be17867b4136d62646c37f742d329807a7e9f54a57164eec05c8bab2bb1f7462a2
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Berner Wik, Petter
By organisation
Department of Building Engineering, Energy Systems and Sustainability Science
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 336 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 617 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf