Evaluation of field calibration methods and performance of AQMesh, a low-cost air quality monitor.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Electrical Engineering, Mathematics and Science, Chemistry.ORCID iD: 0000-0002-0288-8176
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Electrical Engineering, Mathematics and Science, Chemistry.ORCID iD: 0000-0002-8985-2562
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0002-0337-8004
2021 (English)In: Environmental Monitoring & Assessment, ISSN 0167-6369, E-ISSN 1573-2959, Vol. 193, no 5, article id 251Article in journal (Refereed) Published
Abstract [en]

Field calibrations of NO2, NO, and PM10 from AQMesh Air Quality Monitors (AQMs) were conducted during a summer and an autumn period in a busy street in a midsize Swedish city. All the three linear calibration procedures studied (postscaled, bisquare, and orthogonal data) significantly reduced the ranges and magnitudes of the performance indicators to yield more reliable results than the raw data. The improvements were sufficient to satisfy the European Union (EU) Data Quality Objective (DQO) for indicative measurements as compared to reference data only for NO2 (above 50 µg m-3) and NO (above 30 µg m-3) during the autumn calibration period. The relatively simple bisquare procedure had the best performance overall. The bisquare procedure improved the root mean square error by the same amount as other studies using complex multivariate calibration methods. Low concentrations of pollutants were measured, far below the EU Environmental Quality Standard thresholds and even satisfying the future goals for the Environmental Quality Objectives. Cleaning the raw data by removing data points in the reference data that were below the reference station limit of detections (and the synchronous data points in the AQM prescaled data) was found to improve the performances of the calibration procedures appreciably. Many NO2 and almost all PM10 data points in this study fell below the AQM limit of detection. These low concentrations will probably be a common problem in many field studies, at least in areas with relatively low air pollution. However, the relative errors were sufficiently low for these data points that they could be interpreted as accurately representing low concentrations and did not need to be removed from the datasets. For the NO2 measurements, a slight periodic error correlated with sunlight and increased ambient temperature was noted. NO measurements correlated strongly with increased traffic.

Place, publisher, year, edition, pages
Springer , 2021. Vol. 193, no 5, article id 251
Keywords [en]
AQMesh, Bisquare linear fit, Linear calibration, Low-cost air quality monitor, Orthogonal regression
National Category
Civil Engineering
Research subject
Sustainable Urban Development
Identifiers
URN: urn:nbn:se:hig:diva-35650DOI: 10.1007/s10661-021-09033-xISI: 000639224800003PubMedID: 33834306Scopus ID: 2-s2.0-85104089741OAI: oai:DiVA.org:hig-35650DiVA, id: diva2:1544948
Funder
Vinnova, 2016-04223Available from: 2021-04-16 Created: 2021-04-16 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

fulltext(2532 kB)352 downloads
File information
File name FULLTEXT01.pdfFile size 2532 kBChecksum SHA-512
576d8b2f73033e131fbf59185d06e4fd73d53e1bca757529a773b3826ec1d8f25471132bf627f26b427a3df9f520553a078db0847d92c3e09c724bfcd892966e
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Authority records

Wahlborg, DanBjörling, MikaelMattsson, Magnus

Search in DiVA

By author/editor
Wahlborg, DanBjörling, MikaelMattsson, Magnus
By organisation
ChemistryEnergy Systems and Building Technology
In the same journal
Environmental Monitoring & Assessment
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 353 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 525 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf