Experimental characterization of an amplifier's nonlinear properties at 24 GHz is presented in single and dual-band operation using orthogonal frequency-division multiplex signals. A test system for characterizing an amplifier's nonlinear properties at millimeter-wave frequencies for single and dual-band excitation is presented. The use of standard instrument enables a feasible test system. Analytical expressions based on a statistical analysis of signals and hardware impairments were used to analyze the experimental data versus power level and found to describe well the experimental results, including inter- and cross-modulation distortion. Parameters are derived that could be used in system studies.