hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Stiffness of concrete-filled thin-walled steel tubular slender columns
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology. Department of Civil Engineering, Abadan Branch, Islamic Azad University, Abadan, Iran.ORCID iD: 0000-0002-9431-7820
Department of Civil Engineering, Abadan Branch, Islamic Azad University, Abadan, Iran.
2021 (English)In: Civil and Environmental Engineering, ISSN 1336-5835, Vol. 17, no 1, p. 252-258Article in journal (Refereed) Published
Abstract [en]

Concrete-filled thin-walled steel tubular slender columns are studied in this paper to evaluate their stiffness. The slender columns have various steel tube thicknesses, length/diameter (width) ratios, and concrete compressive strengths. The columns are loaded by axial and eccentric loads. Two experimental tests of the slender and stub columns are described. Also, the finite element software ABAQUS is utilised to simulate and analyse the columns. The tested columns are simulated taking into account all of their features in the tests to verify the simulation of the columns. The simulation results are compared with the tests results which reveal that good agreements exist between them. Thus, the proposed simulation method of the columns is verified. In order to assess the stiffness of the columns under different conditions, various load eccentricities (0 mm, 25 mm, and 50 mm), cross-sectional configurations (circular, rectangular, and square), and steel tube thicknesses (2 mm, 3.35 mm, and 5 mm) are adopted for the developed columns. The columns are simulated and analysed based on the verified simulation method considering the mentioned conditions. As a conclusion, the stiffness of the columns is generally reduced by the increase of the load eccentricity from 0 mm to 25 mm and 50 mm. Further, more uniform distribution of the stiffness is witnessed for the columns with lower eccentricities. In addition, the enhancement of the load eccentricity increased the reduction slope of the stiffness graph for the columns. Although the initial stiffness of the circular column is slightly lower than the rectangular and square columns, the stiffness has more uniform distribution which is preferred. Larger stiffness is achieved for the columns by increasing the steel tube thickness from 2 mm to 3.35 mm and 5 mm.

Place, publisher, year, edition, pages
De Gruyter , 2021. Vol. 17, no 1, p. 252-258
Keywords [en]
Stiffness; Steel tube; Concrete core; Finite element method; Concrete-filled column.
National Category
Civil Engineering
Research subject
no Strategic Research Area (SFO)
Identifiers
URN: urn:nbn:se:hig:diva-35967DOI: 10.2478/cee-2021-0026ISI: 000665749300026Scopus ID: 2-s2.0-85106599086OAI: oai:DiVA.org:hig-35967DiVA, id: diva2:1561279
Available from: 2021-06-07 Created: 2021-06-07 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Bahrami, Alireza

Search in DiVA

By author/editor
Bahrami, Alireza
By organisation
Energy Systems and Building Technology
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 271 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf