Numerical Investigation of the Near FieldZone Flow Behavior of Isothermal CornerImpinging Jet Ventilation Using CFD
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science.
2021 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Sustainable development
The essay/thesis is mainly on sustainable development according to the University's criteria
Abstract [en]

Abstract

The impinging jet ventilation's importance in providing better air distribution and energy-efficient operation, as well as both its heating and cooling flexibility potential cannot be overemphasized. This is because acceptable indoor air quality and its environmental conditions are essential to occupant’s wellbeing, comfort, productivity, and improved cognitive function. Poor air quality conditions could result in sick building symptoms (SBS) and several studies have investigated that the prevalence of sick building symptoms is associated with indoor air quality. Consequently, to the need for high ventilation effectiveness, the impinging jet ventilation system has been developed and applied in different types of buildings as a new ventilation strategy and concept within the last two decades. Therefore, it is important to continuously develop inventive air distribution systems such as IJV with a better location and terminal configuration of the supply device to adequately provide an acceptable indoor environment in an energy-efficient manner. This study aims at reaching a comprehensive understanding of the near field zone of an isothermal turbulent corner impinging jet in a room by using computational fluid dynamics (CFD) simulation tool. Thus, directly investigating the flow field involving the velocity magnitude, velocity decay, and spreading rate along the diagonal of the room.The cases carried out consist of 12 different three-dimensional modeled configurations (room) of the computational domain with the dimension 7.0 (L) x 7.0 (W) x 2.67 (H) m. The cases which comprised different aspects of diffuser geometry (triangle, quadrant, square), diffuser area, discharge height, and flow rates, used the RNG k-ε turbulence model to solve the turbulence flow.The result obtained, from the parametric study in all the cases was detailed to analyze the effect of the different flow rate, discharge heights, diffuser geometry, and its area on the velocity profile development, velocity decay, and spreading rate along the diagonal of the room. This study significantly shows the triangular geometries having greater velocity magnitude and velocity decay along all the line profile positions. Interestingly, a comparison between the quadrant and square geometry illustrates that their characteristics of generating a greater velocity magnitude depend on its discharge height. The result also demonstrated a decrease in jet velocity decay with an increase in jet discharge height. With similar jet spread at higher jet discharge, the square geometry exhibited a higher spreading rate at lower discharge height.

Place, publisher, year, edition, pages
2021. , p. 50
Keywords [en]
Ventilation, Computational fluid dynamics
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-35982OAI: oai:DiVA.org:hig-35982DiVA, id: diva2:1561767
Subject / course
Energy systems
Educational program
Energy systems – master’s programme (two years)
Available from: 2021-09-10 Created: 2021-06-07 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

fulltext(2439 kB)175 downloads
File information
File name FULLTEXT01.pdfFile size 2439 kBChecksum SHA-512
3a503b223ca35e5621269d18bf06e10e9a33e0990aed827cca29768c0ce8a445c61c556224e8768012eb6f300cc9659e1d5198a2b45532f1080e0f711e1416c1
Type fulltextMimetype application/pdf

By organisation
Department of Building Engineering, Energy Systems and Sustainability Science
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 175 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 421 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf