hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Komfort- och energianalys vid installation av markiser på Högskolans i Gävle glasfasader: Mätningar och IDA ICE-simuleringar
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
2021 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Sustainable development
The essay/thesis is partially on sustainable development according to the University's criteria
Abstract [sv]

Högskolan i Gävle planerar att installera solavskärmande markiser på entréhallarnas sydliga glasade fasader. Sedan uppbyggnad har entrébyggnaden som inkluderar ”Rävhallen” och ”Fårhallen” lidit av bristfällig termisk inomhuskomfort på grund av värmeläckage och överhettning orsakade av fasadernas fönsterpartier.

Detta examensarbete gjordes i syfte att via mätningar undersöka den termiska inomhuskomforten i Högskolans i Gävle entréhallar. Arbetet syftade också till att årssimulera och analysera årlig energiförbrukning och termisk inomhuskomfort innan och efter installationen av solavskärmande markiser på byggnadens glasfasader, i simuleringsprogrammet IDA ICE.

En komfortundersökning gjordes genom att mäta termisk komfort och inomhustemperaruter under två tillfällen i april månad. Mätningarna gjordes under en molnig dag och en solig dag vid samma utomhustemperatur, för att undersöka solinstrålningens inverkan på byggnadens termiska komfort och inomhustemperaturer. Komfortundersökningen visade att den termiska komforten i Rävhallen och Fårhallen var undermålig då överhettning uppstår vid hög solinstrålning.

Nödvändiga data inför modellering och simulering insamlades genom observationer, uppskattning, beräkningar och samtal med drifttekniker vid Akademiska hus. Efter datainsamlingen konstruerades en modell i simuleringsprogrammet IDA ICE. Innan simulering validerades modellen med hjälp av tidigare uppmätta temperaturer under april månad. Sedan simulerades byggnadens energiförbrukning och termiska inomhuskomfort över ett helt år, utan markiser, och därefter med markiser.

Resultatet visade att den termiska komforten förbättrades markant vid installation av markiser. Höga topptemperaturer som tidigare förekom i byggnaden minskade eftersom markiserna reducerade solinstrålningen genom fasadens fönsterpartier. Det totala årliga energibehovet ökade dock från 605 MWh till 635 MWh. Det årliga energibehovet för kyla minskade något från 3,4 MWh till 3,2 MWh. Att energiförbrukningen ökade berodde på att markiserna reducerade nyttig gratisvärme från solinstrålningen, särskilt under uppvärmningssäsong. För vidare forskning föreslås en mer effektiv styrteknik av markiserna och en mer detaljrik simuleringsmodell för att få tillförlitligare resultat. Vid tillämpning av bättre anpassad styrning av markiserna bedöms energibesparingspotentialen bli större. Slutsatsen drogs att markiser kan förbättra den termiska inomhuskomforten avsevärt, men att energiförbrukningen kan komma att öka beroende på styrteknik.

Abstract [en]

The University of Gävle plans to install solar shading awnings on the southern glass facades of the main entrances. Since construction, the main entrances Rävhallen and Fårhallen have suffered from poor thermal indoor comfort due to heat leakage and overheating due to the windows on the facades.

This thesis was done in order to map and investigate the thermal indoor comfort in the University of Gävle's main entrances. The work also aimed to simulate and analyze annual energy consumption and thermal indoor comfort before and after the installation of solar shading awnings on the building's glass facades, in the simulation program IDA ICE.

A comfort survey was conducted by measuring thermal comfort and indoor temperature ranges on two occasions in April. The measurements were made during a cloudy day and a sunny day at the same outdoor temperature, to investigate the effect of solar radiation on the building's thermal comfort and indoor temperatures. The comfort survey showed that the thermal comfort in Rävhallen and Fårhallen was insufficient as overheating occurs at high solar radiation.

Data necessary for modeling and simulation was collected through observations, estimates, and dialogs with operating technicians from Akademiska hus. After data collection, a model was constructed in the simulation program IDA ICE. Before simulation, the model was validated using previously measured temperatures during the month of April. Then the building's energy consumption and thermal indoor comfort were simulated over a whole year, without awnings, and with awnings.

The results showed that the thermal comfort was significantly improved by the awnings installations. High peak temperatures that previously occurred in the building decreased because of the reduced solar radiation through the glass facade. The total annual energy demand increased from 605 MWh to 635 MWh. However, the annual energy demand for cooling decreased from 3,4 MWh to 3,2 MWh. The increase in energy consumption was due to the awnings reducing useful heat from solar radiation, especially during the heating season. Prior to further research, a more efficient control technique of the awnings and a more detailed model to improve the simulation results are proposed. When applying better adapted control of the awnings, the energy saving potential is considered to be greater. It was concluded that awnings can significantly improve indoor thermal comfort, but that energy consumption may increase depending on control technology.

Place, publisher, year, edition, pages
2021. , p. 92
Keywords [en]
solar shading, awnings, energy demand, simulation, IDA ICE, indoor thermal com-fort, windows, overheating
Keywords [sv]
solavskärmning, markiser, energiförbrukning, simulering, IDA ICE, termisk komfort, fönster, överhettning
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-36108OAI: oai:DiVA.org:hig-36108DiVA, id: diva2:1563692
Subject / course
Energy systems
Educational program
Energy systems – bachelor’s programme (in eng)
Supervisors
Examiners
Available from: 2021-06-17 Created: 2021-06-10 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

fulltext(3381 kB)317 downloads
File information
File name FULLTEXT01.pdfFile size 3381 kBChecksum SHA-512
11c1a07c91b965eb419a0544de94cc9a875774b878d946a9dd6529eadd65209aadd79b52d76538acd4b55fa53451130296a60d745283df5fccce4c6a98dd8f6b
Type fulltextMimetype application/pdf

By organisation
Energy Systems and Building Technology
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 318 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1202 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf