hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The Church of Jesus Christ of Latter-day Saints in Trollhättan Energy optimization
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science.
2021 (English)Independent thesis Advanced level (degree of Master (One Year)), 40 credits / 60 HE creditsStudent thesis
Sustainable development
The essay/thesis is mainly on sustainable development according to the University's criteria
Abstract [en]

The world is experiencing increasing energy usage owing to environmental impacts suchas climate change, Ozone layer depletion, and global warming. Energy usage is primarily categorized into transport, industrial, residential, and service sectors, with the transportation and industrial sectors taking up a considerable chunk of the energy use; Buildings partly determine the use of energy globally. This review presents a critical analysis of energy demand and uses in the building sector considering the energy optimization for The Church of Jesus Christ of Latter-day Saints in Trollhättan, including the local energy requirements. The modelling software IDA-ICE isused to conduct simulations for different scenarios. The IDA-ICE software links the actual building images with the isometric views done on a computer. The energy balance of buildings is considered with respect to the three methods for heat transfer, the U-value,ventilation, heating load, and cooling load. The study results show that the building relieson electricity and fuel for its energy supply and that fuel consumption takes the highest share, 60 %. Retrofit 1 (where the oil and electric boilers are replaced by geothermal heat pump with COP 4 for heating and domestic hot water), Retrofit 2 (which keeps changes from Retrofit_1 and where a new AHU with a VAV system replaces the existing two AHUs), and Retrofit 3 (which keeps changes from Retrofit_2 and only connects the heating system to district heating) are designed as part of the findings to understand the variation sin comfort reference, supplied Energy, used Energy, utilized Energy, auxiliary Energy, and the Energy of all zones during heating and cooling. The model results indicate that Retrofit2 demonstrates better results than the other two since it has a higher energy-saving capacity. The energy reduction for Retrofit model 1 is about 33.4 %, while Retrofit model 2 has 55% and model 3 has 33%, significantly decreasing the associated costs. The LCC analysis shows payback for the first model 6.73 years with an investment cost of 700 000 SEK, the second model has 5.84 with 1 million SEK investment, and the third model has 3.4 years with 350 000 SEK.

Place, publisher, year, edition, pages
2021. , p. 103
Keywords [en]
Energy performance, Energy retrofits, Energy optimization, IDA-ICE, LCC analysis
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-36586OAI: oai:DiVA.org:hig-36586DiVA, id: diva2:1574690
Subject / course
Energy technology
Educational program
Energy engineering – master’s programme online (one year) (in eng)
Supervisors
Examiners
Available from: 2021-07-01 Created: 2021-06-29 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

fulltext(4187 kB)419 downloads
File information
File name FULLTEXT01.pdfFile size 4187 kBChecksum SHA-512
4509df79ffafef751c4442c3a7de938c88513e8e0f82806f4247accc96466c05cf666d44394b558cd5abdf28ef22189065f43216d4e058092c92417198611e18
Type fulltextMimetype application/pdf

By organisation
Department of Building Engineering, Energy Systems and Sustainability Science
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 422 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 934 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf