Resilient cooling strategies – A critical review and qualitative assessmentShow others and affiliations
2021 (English)In: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 251, article id 111312Article in journal (Refereed) Published
Abstract [en]
The global effects of climate change will increase the frequency and intensity of extreme events such as heatwaves and power outages, which have consequences for buildings and their cooling systems. Buildings and their cooling systems should be designed and operated to be resilient under such events to protect occupants from potentially dangerous indoor thermal conditions. This study performed a critical review on the state-of-the-art of cooling strategies, with special attention to their performance under heatwaves and power outages. We proposed a definition of resilient cooling and described four criteria for resilience—absorptive capacity, adaptive capacity, restorative capacity, and recovery speed —and used them to qualitatively evaluate the resilience of each strategy. The literature review and qualitative analyses show that to attain resilient cooling, the four resilience criteria should be considered in the design phase of a building or during the planning of retrofits. The building and relevant cooling system characteristics should be considered simultaneously to withstand extreme events. A combination of strategies with different resilience capacities, such as a passive envelope strategy coupled with a low-energy space-cooling solution, may be needed to obtain resilient cooling. Finally, a further direction for a quantitative assessment approach has been pointed out.
Place, publisher, year, edition, pages
Elsevier, 2021. Vol. 251, article id 111312
Keywords [en]
uilding cooling; Resilient; Climate change; Heatwave; Power outage; Qualitative analysis; Passive cooling; Active cooling; Low-energy cooling; Critical review
National Category
Energy Engineering
Research subject
Sustainable Urban Development
Identifiers
URN: urn:nbn:se:hig:diva-36951DOI: 10.1016/j.enbuild.2021.111312ISI: 000703160100004Scopus ID: 2-s2.0-85112784297OAI: oai:DiVA.org:hig-36951DiVA, id: diva2:1586919
Note
The research is supported by Det Energiteknologisk Udviklingsog Demonstrationsprogram (EUDP) under grant 64018-0578. It was also supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Building Technologies Office of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231
2021-08-232021-08-232025-10-02Bibliographically approved