Smart dosimetry by pattern recognition using a single photon counting detector system in time over threshold mode
Mittuniversitet.
Show others and affiliations
2012 (English)In: Journal of Instrumentation, E-ISSN 1748-0221, Vol. 7, no 1, article id C01027Article in journal (Refereed) Published
Abstract [en]

The function of a dosimeter is to determine the absorbed dose of radiation, for those cases in which, generally, the particular type of radiation is already known. Lately, a number of applications have emerged in which all kinds of radiation are absorbed and are sorted by pattern recognition, such as the Medipix2 application in [1]. This form of smart dosimetry enables measurements where not only the total dosage is measured, but also the contributions of different types of radiation impacting upon the detector surface. Furthermore, the use of a photon counting system, where the energy deposition can be measured in each individual pixel, ensures measurements with a high degree of accuracy in relation to the pattern recognition. In this article a Timepix [2] detector system has been used in the creation of a smart dosimeter for Alpha, Beta and Gamma radiation. When a radioactive particle hits the detector surface it generates charge clusters and those impacting upon the detector surface are read out and image processing algorithms are then used to classify each charge cluster. The individual clusters are calculated and as a result, the dosage for each type of radiation is given. In some cases, several particles can impact in roughly the same place, forming overlapping clusters. In order to handle this problem, a cluster separation method has been added to the pattern recognition algorithm. When the clusters have been separated, they are classified by shape and sorted into the correct type of radiation. The algorithms and methods used in this dosimeter have been developed so as to be simple and computationally effective, in order to enable implementation on a portable device. © 2012 IOP Publishing Ltd and SISSA.

Place, publisher, year, edition, pages
2012. Vol. 7, no 1, article id C01027
Keywords [en]
Dosimetry, Pattern Recognitionm, Single Photon Counting Detector, Time over Threshold Mode, Radiology, Nuclear Medicine and Medical Imaging, Radiologi och bildbehandling, Medical Image Processing, Medicinsk bildbehandling, Accelerator Physics and Instrumentation, Acceleratorfysik och instrumentering
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hig:diva-37256DOI: 10.1088/1748-0221/7/01/C01027OAI: oai:DiVA.org:hig-37256DiVA, id: diva2:1605322
Available from: 2021-10-22 Created: 2021-10-22 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Reza, Salim

Search in DiVA

By author/editor
Reza, Salim
In the same journal
Journal of Instrumentation
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 111 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf