Assessment of glulam and reinforced concrete beams in multi-storey building
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0002-9431-7820
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
2022 (English)In: Civil and Environmental Engineering, ISSN 1336-5835, Vol. 18, no 1, p. 66-75Article in journal (Refereed) Published
Abstract [en]

This study assesses glulam and reinforced concrete (RC) beams in a multi-storey building in Gävle in Sweden. StruSoft FEM-Design software is used to conduct the current study. First, the building having the RC beams is modelled, analysed, and designed. Utilisation ratio, stress, weight, reaction force, stability, and deflection of the building are examined. It is concluded that the building can function well with RC beams. Then, the RC beams are replaced with glulam beams and the building is again analysed. It is revealed that larger cross-sections are needed for the replaced glulam beams in most of the spans compared with the RC beams in order for them to have acceptable results from the utilisation ratio viewpoint. However, for large spans of 8 m, a timber column is used in the mid-span for all the storeys as a strengthening alternative so that a shorter span for these glulam beams can be adopted which leads to acceptable results. Stresses of the RC and glulam beams are also evaluated. The building having the glulam beams is 23.79 % lighter than the building having the RC beams. The maximum reaction force of the building having the glulam beams is obtained 24.27 % lower than the building having the RC beams. Stability and deflection of the building in both cases are discussed as well.

Place, publisher, year, edition, pages
Sciendo , 2022. Vol. 18, no 1, p. 66-75
Keywords [en]
Glulam, Reinforced concrete, Beam, Utilisation ratio, Reaction force
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:hig:diva-38820DOI: 10.2478/cee-2022-0007ISI: 000800649800001Scopus ID: 2-s2.0-85134029699OAI: oai:DiVA.org:hig-38820DiVA, id: diva2:1666616
Available from: 2022-06-09 Created: 2022-06-09 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

fulltext(762 kB)204 downloads
File information
File name FULLTEXT01.pdfFile size 762 kBChecksum SHA-512
f6ce809fbeec1b1dbd3b0a8630426820dc1dd22a5c66323ebac4503f633363cdbc6bd73a89e1e9d2cf63b493a1ef8e0bfe3e7844d25299d3b3c2a8600539b54a
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Bahrami, Alireza

Search in DiVA

By author/editor
Bahrami, AlirezaAzizian, Dawod
By organisation
Energy Systems and Building Technology
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 206 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 511 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf