hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Space Heat Power Demand for Existing Buildings: Feasibility, Improvement-Measures, and Impact on Climate Performance Using a Swedish Multi-Dwelling Building as Case Study
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
2022 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

The most commonly used indicators of energy performance of existing buildings in Sweden, Specific Energy Use (SEU) and Primary Energy Use (PEU), are very rough measures that does not account for short term effects and therefore they are not necessarily well suited to evaluate climate performance of existing buildings. In this thesis the similar but slightly different indicators Miljöbyggnad Heat Power Demand (MHPD) (Värmeeffektbehov in Swedish) and Feby Heat Loss Number (FHLN) (Värmeförlusttal in Swedish), both indicators of Space Heat Power Demand (SHPD), has been evaluated as complementary indicators to SEU and PEU. SHPD focus on energy lost through transmission, infiltration, and ventilation and it is evaluated at Dimensioning Winter Outdoor Temperature (DWOT). The thesis has been done in cooperation with the consultancy company WSP and the housing company Rikshem. Rikshem has provided building construction data and energy data for a multi-dwelling building located in Norrköping, Sweden. The data has been used to find SHPD through (1) linear regression of the building energy signature, (2) simplified manual calculations, and (3) simulations in the dynamic energy calculation software IDA ICE. Results from the different methods and the use of the methods themselves have then been analyzed and compared. In a subsequent step different energy measures that affect SHPD has been simulated and the impact on both SHPD, SEU, and PEU has been evaluated to see both short term impact and impact on yearly energy use. For the studied building the SHPD-value for linear regression of energy signature was lowest (33.3 W/m2,Atemp), followed by the value for dynamic energy simulation (36.7 W/m2,Atemp). Highest was the value for simplified manual calculation (38.8 W/m2,Atemp). The relatively small difference indicate that it could be feasible to map a building stock using different methods. However, this study has been limited to examining one non-complex building and it is likely that many difficulties will arise if a larger set of buildings with different complexities and conditions would be analyzed. If worked with, these difficulties can likely be overcome through gaining more knowledge of the construction of buildings and measuring of hourly energy use for each building. Focus on SHPD of buildings would mainly favor improvement of buildings’ climate shells, and such measures are, in general, good for mitigation of negative climate impact of buildings. Depending on if the Miljöbyggnad- or the Feby- definition of SHPD is used, different ventilation heat recovery measures can be favored. Climate impact of the different ventilation heat recovery measures can be both negative and positive depending on composure of the energy system around the building and depending on boundaries of analysis.

Place, publisher, year, edition, pages
2022. , p. 40
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:hig:diva-39913OAI: oai:DiVA.org:hig-39913DiVA, id: diva2:1694697
External cooperation
WSP Sverige AB
Subject / course
Energy systems
Educational program
Energy systems – master’s programme (two years)
Supervisors
Examiners
Available from: 2022-10-04 Created: 2022-09-10 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

fulltext(1603 kB)277 downloads
File information
File name FULLTEXT01.pdfFile size 1603 kBChecksum SHA-512
b033fca7fb1fd723a4998b085481bef1ad7b56c243870c5b7f865ca20c56314e83318b4537d156482712f280e7fdc089951c7502e4e15ca41737a674d288aeae
Type fulltextMimetype application/pdf

By organisation
Energy Systems and Building Technology
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 279 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 258 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf