hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Numerical analysis of wind-induced natural ventilation for an isolated cubic room with two openings under small mean wind pressure difference
Osaka University, Japan.ORCID iD: 0000-0003-4956-1274
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0003-1121-2394
Osaka City University, Japan.
Toyo University, Japan.ORCID iD: 0000-0002-6038-9383
Show others and affiliations
2022 (English)In: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 226, article id 109694Article in journal (Refereed) Published
Abstract [en]

Wind-induced natural ventilation through openings with small wind pressure differences was examined using large eddy simulation (LES) modelling. This study focused on cases in which the ventilation rate is predicted using a standard Orifice equation. The purpose of this study was to clarify how the ventilation rate is underestimated in such cases for both single-sided and double-sided openings, and to clarify the difference between the effective ventilation rate (purging flow rate, PFR) and bulk airflow rate (AFR), which have not been sufficiently and systematically understood. A simple cubic-room model with two openings was analysed using LES by varying the opening position after validation, and the ventilation rate, velocity field, and wind pressure coefficient were compared with experimental results. The PFR was determined by tracing particles, and the AFR was obtained based on the instantaneous velocity over the openings. The AFR predicted by the Orifice equation was underestimated when the difference in the mean wind pressure coefficient (Delta(C-p) over bar) was less than 0.1. The main feature of this study was to show the ventilation effectiveness defined by the PFR divided by AFR, which was approximately 70-80%, 60%, and 90% for the double-sided openings, single-sided openings on the lateral side, and windward and leeward sides, respectively. Another feature was to propose a method for estimating the AFR reflecting two key phenomena, namely pulsating flow and eddy penetration. In addition, a simple equation considering the standard deviation of wind pressure coefficient difference (sigma(Delta Cp)), and external local velocity around an opening (V-vic) was obtained.

Place, publisher, year, edition, pages
Elsevier , 2022. Vol. 226, article id 109694
Keywords [en]
Natural ventilation, Single-sided ventilation, Cross-ventilation, Wind tunnel test, CFD
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:hig:diva-40506DOI: 10.1016/j.buildenv.2022.109694ISI: 000878643200004Scopus ID: 2-s2.0-85140302173OAI: oai:DiVA.org:hig-40506DiVA, id: diva2:1713209
Available from: 2022-11-24 Created: 2022-11-24 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Sandberg, Mats

Search in DiVA

By author/editor
Kobayashi, TomohiroSandberg, MatsLim, EunsuUmemiya, Noriko
By organisation
Energy Systems and Building Technology
In the same journal
Building and Environment
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 104 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf