hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
FAST-AIR: Fast analytic systems for tracer-gas assessment in indoor research: Development and testing of CO2 tracer-gas system.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0002-7926-7378
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Industrial Management, Industrial Design and Mechanical Engineering.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology. (Energy Systems)ORCID iD: 0000-0003-1121-2394
Show others and affiliations
2025 (English)In: ROOMVENT 2004, Stockholm: EDP Sciences , 2025, Vol. 672, article id 02007Conference paper, Published paper (Refereed)
Abstract [en]

The time constant of ventilation of rooms in buildings is between 15 minutes (in office spaces) to 2 hours (in residential buildings). Currently, most of the tracer gas system analyzers on the market have a minute-based time constant and depending on the channels a cycle of sampling and analysis may take up to 6 minutes, E.g., 6 channel system. Essentially, only mean values are recorded with most present tracer gas analyzers. This is a hindrance for detailed temporal analysis of conditions in the room and consequently is does not capture the resolution of the influence of the internal flow on air and contaminant distribution. The current paper presents work on the development and testing of a fast response CO2 tracer-gas system with a time constant of 1 second. In contrast to the present analyzers, not only the mean values but also the whole statistical distribution of variables can be recorded, and pulse responses can be analyzed. This makes the system viable for measurement and analysis of not only spatial but also temporal distribution of contaminants. For example, recirculating airflow in the room generated by flooding of ventilation air is possible to be measured and thus making it easy to extend the analyses of the process of ventilation far beyond the possibilities with current systems.

Place, publisher, year, edition, pages
Stockholm: EDP Sciences , 2025. Vol. 672, article id 02007
Series
E3S Web of Conferences, E-ISSN 2267-1242 ; 672
Keywords [en]
Tracer-gas Analyzer, fast response, temporal distribution, contaminant transport, indoor measurements
National Category
Mechanical Engineering Building Technologies
Research subject
Sustainable Urban Development
Identifiers
URN: urn:nbn:se:hig:diva-44121DOI: 10.1051/e3sconf/202567202007ISI: 001740143800066Scopus ID: 2-s2.0-105031144996OAI: oai:DiVA.org:hig-44121DiVA, id: diva2:1854806
Conference
ROOMVENT 2024, Stockholm, 22-24 April
Part of project
Ventilation as a strategy to reduce indoor transmission of airborne diseases: development of new strategies and a risk assessment model, Swedish Research Council Formas
Funder
Swedish Research Council Formas, 2021-01606Available from: 2024-04-26 Created: 2024-04-26 Last updated: 2026-05-18Bibliographically approved

Open Access in DiVA

fulltext(2606 kB)13 downloads
File information
File name FULLTEXT02.pdfFile size 2606 kBChecksum SHA-512
2a6917aeef8bf60ab1650910831bac0de24df5b9e712936b837ad13d7fdbfd123bf82a0ce5ab9f3d6a5f1b89284d09b45929dbe97a22d06d8916b278a4750b3b
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Andersson, HaraldSandberg, MatsKabanshi, Alan

Search in DiVA

By author/editor
Andersson, HaraldSundberg, MikaelSenkic, DarioSandberg, MatsKabanshi, Alan
By organisation
Energy Systems and Building TechnologyDepartment of Building Engineering, Energy Systems and Sustainability ScienceDepartment of Industrial Management, Industrial Design and Mechanical Engineering
Mechanical EngineeringBuilding Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 163 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 969 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf