Vilken risk för kondens finns i ett kallställt hus? Fallstudie av Hälsingegården Erik-Anders.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science.
2023 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Byggnader som står tomma under de kalla delarna av året värms oftast inte upp under denna tid. Nu när elpriserna blir dyrare väljer fler personer att kallställa sina fritidsboenden. Detta kan medföra stora problem med fukt och mögel. För att undvika detta behöver den relativa luftfuktigheten inomhus sänkas för att minimera risken för kondens och fuktskador. Detta kan göras med hjälp av avfuktare som minskar fuktinnehållet hos inneluften.

I detta arbete ska en fallstudie av världsarvet hälsingegården Erik-Anders utföras för att sedan kunna besvara frågan om vilken risk för kondens som finns vid snabba väderomslag och hur byggnadens termiska tröghet och luftläckaget påverkar risken för kondens. Studien har bestått av ett platsbesök där data samlats in i form av mått och materialinventering. Denna data kombinerat med tidigare uppmätt data har sedan legat till grund för modellering av byggnaden och simulering i IDA-ICE. I programmet har rumsluftens temperatur och luftfuktighet simulerats för att sedan för hand kunna beräkna risken för kondens.

Resultatet här blev att vid varma utetemperaturer med hög relativ luftfuktighet kort efter kalla väderlekar uppstår mycket kondens i den kallställda byggnaden. Utöver detta bidrar även ett högt luftläckage till att topparna av den relativa luftfuktigheten hos inneluften blir något högre. Simuleringarna har även påvisat att en högre termisk tröghet bidrar till större fördröjning i inomhustemperaturerna vilket resulterat i ökad mängd avgiven kondens.

När luftläckaget ökar tränger mer varm luft in vilket kan bidra till mer kondens. Ett problem är att vindpåverkan inte studerats i denna fallstudie vilket kan bidra till osäkerheter mellan simulerade resultat och uppmätta resultat, detta kan därav kräva vidare forskning. Simuleringar ska baseras på indata som är relevant till objektet men denna data kan inte undersökas i detalj vilket medför osäkerheter i resultatet. Simulerade resultat förväntas därmed skilja sig något från uppmätta, men det är trenderna och tendenserna som är viktigast.

Från denna information kan slutsatsen dras att höga utelufttemperaturer i kombination med hög relativ luftfuktighet bidrar till en högre risk för kondens i Hälsingegården vid snabba väderomslag från kallt till varmt.

Abstract [en]

Buildings that are left unoccupied during the cold periods of the year are also often left unheated during that time. With the electricity prices getting higher it can be assumed that more people will leave their summerhouses unheated. This may bring a lot of problems with mould and moisture. To avoid this the relative humidity inside the building needs to be kept low to minimize the risk of condensation and other damages. This can be done with dehumidifiers.

This case study of the world heritage Decorated Farmhouse of Hälsingland, Erik-Anders, aims to answer the question of how high the risk is for condensation when the weather changes from cold to warm quickly. Also, the thermal inertia of the building and the air leakage will be considered. The study has consisted of a site visit where measurements of the building were taken, and materials were documented. This data combined with data that has been measured beforehand were combined in the modelling of the building and simulation in IDA-ICE. Indoor air temperatures and relative humidity has been simulated and then the risk of condensation has been calculated.

The result showed that when warm outdoor air temperatures with a high relative humidity occurred shortly after cold weather, the risk of condensation is high in the cold building. Furthermore, the results showed that high leakage into the building contributed to higher peaks in indoor relative humidity. The simulation also showed that a concrete construction contributed to a greater lag in indoor temperature which resulted in increased condensation.

πA problem with this study is that the impact of wind has not been studied which leads to uncertainties between simulated and measured results, this may need further studying. Simulations should be based on data that is relevant to the object but considering that this data cannot be examined in detail results in uncertainties in the result. Simulated results can be expected to differ from the measures results, but it is the trends and tendencies that is of importance in this study.

From this information the conclusion can be drawn that high outer temperatures combined with high relative humidity contributes to a higher chance of condensation in the farmhouse.

Place, publisher, year, edition, pages
2023. , p. 68
Keywords [en]
condensation, Hälsingegård, cold air, leakage, thermal inertia
Keywords [sv]
kondens, Hälsingegård, kallställd, luftläckage, tröghet
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:hig:diva-45789OAI: oai:DiVA.org:hig-45789DiVA, id: diva2:1903855
Subject / course
Building engineering
Educational program
Högskoleingenjör
Supervisors
Examiners
Available from: 2024-10-15 Created: 2024-10-07 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

fulltext(4656 kB)226 downloads
File information
File name FULLTEXT01.pdfFile size 4656 kBChecksum SHA-512
1fd0923f7fbd67bbe2bbcee0f2d5f4044fb5e65b51f88a877565cd87d3a433b62a5879f7f7009c841e5987d9bb05afe3f52282925d8d3f166dc24ee221747ab1
Type fulltextMimetype application/pdf

By organisation
Department of Building Engineering, Energy Systems and Sustainability Science
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 228 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 230 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf