hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Indoor Environmental Quality — Ventilation
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0003-1121-2394
2024 (English)In: Encyclopedia of Sustainable Technologies / [ed] Martin A. Abraham, Elsevier , 2024, 2, p. 306-321Chapter in book (Other academic)
Abstract [en]

The primary goal of ventilation is to provide dilution capacity for lowering the concentration of contaminant by diluting contaminants generated within a room. First is discussed the properties of the dilution curve which is the concentration as a function of the ventilation flow rate and the varying efficiency of dilution at different levels of concentration. The concept purging flow rate which is the flow rate that ventilates is introduced. In situations where the supply air is laden with the contaminant that is going to be removed it is important to distinguish between the purging flow rate and the flow rate supplied by the ventilation system. The trade-off between control of contaminant levels by ventilation and source control is addressed. Factors that may diminish the dilution capacity as short circuiting and direct loss of air are dealt with. A sensation of draught may be counteracted by the occupants’ manipulation of the ventilation system which may lead to reduced dilution capacity. Situations where there is a risk of draught occurring are identified and design parameters are introduced whose use in design can help in avoiding systems that cause draught. Communication about how ventilation works is important for avoiding mistakes and wrong expectations about what can be achieved with ventilation. 

Place, publisher, year, edition, pages
Elsevier , 2024, 2. p. 306-321
Keywords [en]
Air Distribution; Dilution capacity; Draught; Evacuation capacity; Flooding of ventilation air; Internal flow; Purging flow rate; Recirculation; Spreading of contaminants by the Ventilation; Tracer gas technique; Ventilation; Visualization
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-46733DOI: 10.1016/b978-0-323-90386-8.00118-2Scopus ID: 2-s2.0-105000577982ISBN: 978-0-443-22287-0 (print)OAI: oai:DiVA.org:hig-46733DiVA, id: diva2:1950255
Available from: 2025-04-07 Created: 2025-04-07 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Sandberg, Mats

Search in DiVA

By author/editor
Sandberg, Mats
By organisation
Energy Systems and Building Technology
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 20 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf