Experimental study on performance improvement and energy savings of split-type air conditioning system using direct evaporative cooling in hot Iraqi climate
University of Kerbala, Iraq.
University of Kerbala, Iraq.
University of Kerbala, Iraq.
University of Kerbala, Iraq.
Show others and affiliations
2026 (English)In: International Communications in Heat and Mass Transfer, ISSN 0735-1933, E-ISSN 1879-0178, Vol. 177, article id 111507Article in journal (Refereed) Published
Abstract [en]

The challenge of electricity consumption is one of the most pressing Global issues today. Air-conditioning systems represent a major part of this consumption, and their impact is even more visible in hot-desert climate. A practical approach to mitigate this problem is to pre-cooled ambient air before it enters the outdoor unit, which not only improves system performance. In this experimental study, a split-type air conditioner of 1.5-ton capacity was tested under the summer conditions of Karbala city, Iraq. Direct evaporative cooling technique was adopted using a 100 mm thick cellulose pad, positioned 55 cm away from the outdoor condenser to allow better air-moisture mixing. Comparative measurements were carried out between the conventional units and the modified one. The results showed a reduction in power consumption by up to 24.56% and an increase in coefficient of performance by nearly 37.47%. From an economic point of view, the analysis revealed that the maximum saving in annual electricity cost was about USD 20.45, while the life-cycle saving ranged between USD 220 and USD 365. The payback-time of the initial investment was estimated around 3 years which indicates a relatively short recovery time. Such findings provide a meaningful signal toward adapting environmentally friendly strategies.

Place, publisher, year, edition, pages
Elsevier , 2026. Vol. 177, article id 111507
Keywords [en]
Coefficient of performance; Air conditioning; Evaporative cooling; Energy saving; Payback time
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-49818DOI: 10.1016/j.icheatmasstransfer.2026.111507ISI: 001777734800001Scopus ID: 2-s2.0-105038775782OAI: oai:DiVA.org:hig-49818DiVA, id: diva2:2060314
Available from: 2026-05-17 Created: 2026-05-17 Last updated: 2026-06-08Bibliographically approved

Open Access in DiVA

fulltext(13851 kB)99 downloads
File information
File name FULLTEXT01.pdfFile size 13851 kBChecksum SHA-512
c2af6b2bbd46836ba79a5bd9b74b31f6d9234e5913f3388cdc560a8ed07e0eced75beda7d2a640f7bdd7e2f5a3d265969bc026a9b4fc0e78627c7c077b0707b5
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Ameen, Arman

Search in DiVA

By author/editor
Ameen, Arman
By organisation
Energy Systems and Building Technology
In the same journal
International Communications in Heat and Mass Transfer
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 99 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 228 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf