Långtidsmätning av termisk komfort i datasalar vid Högskolan i Gävle
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
2026 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

En god inomhusmiljö är avgörande för hög produktivitet i en datasal. Föroreningar som inte ventileras bort effektivt resulterar i höga halter av koldioxid och fukt samt värmetillskott från personer och elektronisk utrustning i datasalar, vilket påverkar studenters och lärares hälsa och kognitiva förmåga negativt. Dokumentationen av inomhusklimatet i datasalar vid Högskolan i Gävle saknas. Tre datasalar undersöktes, där datasal A (källarvåning, sydvästfönster, sex sittplatser), datasal B (källarvåning, sydostfönster, nio sittplatser) och datasal C (plan 5, nordostfönster, 30 sittplatser), samtliga med personstyrd ventilation. Långtidsmätningar av koldioxidhalterna, luftfuktigheten och inomhustemperaturen genomfördes under 13–27 april 2026 med Comet dataloggern U3430 på ett mätintervall på 10 minuter. Vidare genomfördes korttidsmätningar med mätinstrumentet Testo 400 under molniga och soliga väderförhållanden i samband med enkätundersökning, där resultaten jämfördes mot ASHRAE 55 och ISO 7730. Resultaten visade att luftfuktigheten i alla datasalar låg i intervallet 20–40 %. Medelstrålningstemperaturen uppfyllde riktlinjerna i samtliga datasalar. Datasal B och C uppfyllde kravet för lufttemperatur på 20–24 °C. Däremot uppfyllde inte datasal A riktlinjer för lufttemperaturen, där den genomsnittliga lufttemperaturen uppmättes till 19,6 °C under 14 dagarsperioden. Lufthastigheten i datasal A och B uppfyllde riktlinjen på 0,15 m/s, medan datasal C överskred gränsen periodvis. Enligt mätresultaten låg koldioxidhalten under 1 000 ppm i datasal A, men överskred 1 000 ppm momentant i datasal B vid ett tillfälle under 14 dagarsperioden. En koldioxidhalt som höll sig över 1 000 ppm under en timme eller längre bryter mot riktlinjer och indikerar att ventilationens funktion är otillräcklig och kräver kontroll och åtgärd, vilket var fallet i datasal C där den genomsnittliga koldioxidhalten låg på 1 073 ppm. Endast datasal C uppfyllde kraven med ett PMV-värde på –0,42. Alla resultat jämfördes mot riktlinjer och samtliga parametrar som inte uppfyllde kraven analyserades vidare och rekommendationer gavs till Högskolan i Gävle.

Abstract [en]

The importance of indoor environments grew significantly following the energy crisis of the 1970s. The energy crisis led the EU to adopt more energy-efficient solutions in buildings. A good indoor environment is essential for productivity in a computer lab. Pollutants that are not effectively removed through ventilation result in elevated levels of carbon dioxide and humidity, as well as heat generated by occupants and electric equipment, which negatively affects the health and cognitive performance of students and teachers. Indoor climate documentation in computer labs at the University of Gävle been absent. Three computer labs were studied, lab A (basement, southwest-facing windows, six seats), lab B (basement, southeast-facing windows, nine seats) and lab C (5th floor, northeast-facing windows, 30 seats), all equipped with demand-controlled ventilation. Long-term measurements of carbon dioxide levels, relative humidity and indoor temperature were carried out between 13–27 April 2026 using the Comet data logger U3430 at a measurement interval of 10 minutes. Short-term measurements were also carried out using the Testo 400 instrument under both cloudy and sunny weather conditions, alongside a questionnaire survey, where the results were compared against ASHRAE 55 and ISO 7730.The results showed that relative humidity in all computer labs fell within the range of 20–40 %. The mean radiant temperature met the guidelines in all computer labs. Computer labs B and C met the air temperature requirement of 20-24 °C. However, computer lab A did not meet the air temperature guidelines, as the average air temperature was measured at 19.6 °C during the 14-day period. Air velocity in computer labs A and B met the guideline of 0.15 m/s, whilst computer lab C periodically exceeded this limit. According to the measurements, carbon dioxide levels remained below 1 000 ppm in computer lab A but momentarily exceeded 1 000 ppm in computer lab B on one occasion during the 14-day period. A carbon dioxide level that remains above 1 000 ppm for one hour or longer is in breach of guidelines and indicates that the ventilation system is insufficient and requires inspection and corrective action, which was the case in computer lab C where the average carbon dioxide level was 1 073 ppm. Only computer lab C met the requirements with a PMV value of –0,42. All results were compared against guidelines, and all parameters that did not meet the requirements were further analysed, after which recommendations were provided to the University of Gävle.

Place, publisher, year, edition, pages
2026. , p. 73
Keywords [en]
Keywords: Thermal comfort, carbon dioxide, indoor air quality, ventilation, PMV/PPD model, long-term measurement, computer lab, questionnaire
Keywords [sv]
Termisk komfort, koldioxidhalt, inomhusmiljö, ventilation, PMV/PPD-modellen, långtidsmätning, datasalar, enkätundersökning
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:hig:diva-50110OAI: oai:DiVA.org:hig-50110DiVA, id: diva2:2070622
Subject / course
Building engineering
Educational program
Högskoleingenjör
Supervisors
Examiners
Available from: 2026-06-17 Created: 2026-06-12 Last updated: 2026-06-17Bibliographically approved

Open Access in DiVA

fulltext(2386 kB)20 downloads
File information
File name FULLTEXT01.pdfFile size 2386 kBChecksum SHA-512
fe3a528c02b157a8d9dea455e726f95a37122f511b0acf338bd55b7f51ca23b514f530bc38f82b87038250e20dadb20557775a99ac728d8e1292f29435052467
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Alsafi, AmirZubaidi, Ahmed
By organisation
Energy Systems and Building Technology
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 107 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf