hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
En jämförande studie avTime-of-Flight och StereoVision för volymuppskattningav granulärt material
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Computer and Geospatial Sciences, Computer Science.
2026 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Uppskattning av volymen av olika material i lösvikt är vanligt förekommande imånga industriella processer[1]. Att noggrant kunna skatta mängden löst material igranulatform är avgörande i doseringsanläggningar för att övervaka materialpåbygg-nad. För att effektivisera och automatisera denna typ av realtidsmätning utan fysiskpåverkan krävs beröringsfri analys, exempelvis genom kameror och 3D-volymetriskrekonstruktion.Syftet med detta arbete är att konstruera kamerabaserade mätsystem (innefattandemjukvara och fysiska experiment) för volymmätning, samt att validera kamerasyste-mens tekniska prestanda. Fokuset är på en jämförande analys mellan två olika mät-tekniker.Projektet använder två USB-baserade 3D-kamerasystem. En PMD-Flexx Time-of-Flight (ToF) kamera och en Intel Realsense 435 stereokamera. Båda kamerorna leve-rerar en depth-image (djupbild), där avståndet mäts i varje pixel. Mjukvaruutveckl-ing utfördes i MATLAB och Python för att läsa in rådata från sensorerna, utföra nu-meriska beräkningar och visualisera den 3D-volymetriska utbredningen av de obser-verade materialen. Tester utfördes i en kontrollerad labbmiljö för att utvärdera sy-stemens mätnoggrannhet.Arbetet resulterade i en teknisk utvärdering som belyser styrkor och svagheter hosToF respektive stereoteknik vid mätning av oregelbundna mängder av granulärtmaterial.

Abstract [en]

Estimating the volume of bulk materials is a common requirement in many indus-trial processes. Accurate estimation of granular materials is crucial in dosing plantsfor monitoring material accumulation. To streamline and automate this type of real-time measurement without physical interference, non-contact analysis is required,for instance, through cameras and 3D volumetric reconstruction.The purpose of this thesis is to design camera-based measurement systems (includingsoftware and physical experiments) for volume measurement, and to validate thetechnical performance of these systems. The focus is on a comparative analysis be-tween two different measurement techniques.The project utilizes two USB-based 3D camera systems: a PMD-Flexx Time-of-Flight (ToF) camera and an Intel RealSense D435i stereo camera. Both cameras pro-vide a depth image, where the distance is measured for each individual pixel. Soft-ware development is conducted in MATLAB and Python to import raw data fromthe sensors, perform numerical calculations, and visualize the 3D volumetric distri-bution of the observed materials. Testing is carried out in a controlled laboratoryenvironment to evaluate the measurement accuracy of the systems.The work resulted in a technical evaluation highlighting the strengths and weak-nesses of ToF and stereo vision technologies, respectively, when measuring irregularquantities of granular material

Place, publisher, year, edition, pages
2026. , p. 37
Keywords [en]
Volume measurement, Stereo Vision, Time-of-Flight, Granular material
Keywords [sv]
Volymmätning, Stereovision, Time-of-Flight, Granulärt material
National Category
Computer and Information Sciences
Identifiers
URN: urn:nbn:se:hig:diva-50275OAI: oai:DiVA.org:hig-50275DiVA, id: diva2:2073969
Subject / course
Computer science
Educational program
Högskoleingenjör
Presentation
2026-06-05, 99:131, 15:10 (Swedish)
Supervisors
Examiners
Available from: 2026-06-25 Created: 2026-06-17 Last updated: 2026-06-25Bibliographically approved

Open Access in DiVA

fulltext(2230 kB)22 downloads
File information
File name FULLTEXT01.pdfFile size 2230 kBChecksum SHA-512
5cf55d81b1371434b9b5c6f3074ef4a8bd9adad9340f6791930a3d8f2ec93a64d8513490c25ed67527b0eac1835408b781c814d50c259720f96e7662da3a36f5
Type fulltextMimetype application/pdf

By organisation
Computer Science
Computer and Information Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 35 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf