Experimental Investigation of Voltage and Air Velocity Effects on Sustainable Thermoelectric Air Conditioning
University of Technology-Iraq, Baghdad, Iraq.ORCID iD: 0009-0000-6664-6638
University of Technology-Iraq, Baghdad, Iraq.ORCID iD: 0000-0003-0359-5022
University of Kerbala, Iraq.ORCID iD: 0000-0002-7609-6585
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0002-8349-6659
Show others and affiliations
2026 (English)In: Energies, E-ISSN 1996-1073, Vol. 19, no 17, article id 4080Article in journal (Refereed) Published
Abstract [en]

Thermoelectric air conditioning (TEAC) systems are gaining attention as refrigerant-free, solid-state cooling technologies due to their compactness, low noise, and environmental benefits. However, their widespread application is constrained by low energy efficiency and the limited experimental understanding of the coupled influence of electrical and aerodynamic operating parameters. Most existing studies address thermoelectric cooling under isolated conditions or rely on theoretical modeling, leaving a clear gap in the experimental quantification of the interactive effects of applied voltage and air velocity on system performance. To address this gap, the present study experimentally investigates a laboratory-scale TEAC system equipped with four thermoelectric cooler (TEC) modules (model TEC1-12706). The system was tested under controlled conditions by varying the input voltage from 6 to 12 V and the air velocity from 1 to 3 m/s. Key performance indicators, including cooling capacity, power consumption, cold-side temperature, and coefficient of performance (COP), were systematically measured and analyzed. The results show that increasing the applied voltage from 6 to 12 V enhances cooling capacity by approximately 50.4%, while significantly increasing electrical power consumption, leading to a 59% reduction in COP due to intensified Joule heating. Conversely, increasing air velocity improves convective heat transfer, resulting in a COP enhancement of about 24% with relatively stable power input. The findings highlight a clear trade-off between cooling capacity and energy efficiency and identify a practical operating region for balanced TEAC performance.

Place, publisher, year, edition, pages
MDPI , 2026. Vol. 19, no 17, article id 4080
Keywords [en]
thermoelectric air conditioning; peltier cooling; coefficient of performance; heat transfer; cooling capacity
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-50948DOI: 10.3390/en19174080ISI: 001872871000001Scopus ID: 2-s2.0-105050364752OAI: oai:DiVA.org:hig-50948DiVA, id: diva2:2097213
Available from: 2026-09-01 Created: 2026-09-01 Last updated: 2026-09-28Bibliographically approved

Open Access in DiVA

fulltext(4454 kB)73 downloads
File information
File name FULLTEXT01.pdfFile size 4454 kBChecksum SHA-512
56258fb5ab520453d6e653f657c3ab22cb6e64d5de36a10c969d5ad0e012509700900c9baaea9f3c943fccb1ce370360fd89608eb37e7fb342a2c1eddfa7e5a1
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Ameen, Arman

Search in DiVA

By author/editor
Ashour, Ali M.Kadhim, Saif AliRashid, Farhan LaftaAmeen, ArmanChaudhry, Imran Ali
By organisation
Energy Systems and Building Technology
In the same journal
Energies
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 73 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 634 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf