This paper describes a method to simultaneously measure the amplitude and phase ripple of two band pass linear systems in cascade by changing the center frequency for one of the systems. Extensive measurements are presented to support the theory. The method has a wide applicability for measurements on RF power amplifiers, transmitters, receivers, etc. The accuracy of the method is in the order of a few hundredths of a dB and one degree for most realistic measurement set-ups.